6.4 ADEC engine governor – Fault codes
29 – HI ETC Idle Speed too High
ZKP-Number: 1.8004.206
Cause
Corrective action
Idle speed of one of the
secondary turbochargers is too
high.
u
Contact Service.
38 – AL ETC Speed Deviation
ZKP-Number: 1.8004.205
Cause
Corrective action
Speeds of one of the secondary
turbochargers deviates from
primary turbocharger speed.
1. Reduce power.
2. Contact Service.
39 – AL ETC2 CutIn Failure
ZKP-Number: 1.8004.204
Cause
Corrective action
ETC2 could not be cut in.
1. Reduce power.
2. Contact Service.
81 – AL Rail Leakage
ZKP-Number: 1.8004.046
Cause
Corrective action
Pressure gradient in rail is too low
during starting or too high during
stopping (HP system leaky or air
in the system)
u
Contact Service.
102 – AL Cons. Counter Defect
ZKP-Number: 1.8004.624
Cause
Corrective action
Consumption meter faulty.
u
Contact Service.
104 – AL Eng Hours Counter Defect
ZKP-Number: 1.8004.623
Cause
Corrective action
Hourmeter faulty.
u
Contact Service.
132 | Troubleshooting | MS150045/03E 2018-08
TIM-ID: 0000018389 - 004
Содержание 12V4000M73 series
Страница 1: ...Operating Instructions Diesel engine 12V4000M73x 16V4000M73x MS150045 03E...
Страница 3: ......
Страница 4: ......