4.2 Putting the engine into operation after extended out-of-service
periods (>3 months)
Preconditions
☑
Engine is stopped and starting disabled.
☑
Preservation and Represervation Specifications A001070/.. are available.
Putting into operation after extended out-of-service periods (>3 months)
Item
Action
Engine
Depreserve (→ MTU Preservation and Represervation Specifications
A001070/..).
Lube oil system
Check engine oil level (→ Page 214);
Preheat engine oil as necessary.
Lubricate valve gear (→ Page 177).
Raw water pump (if located
above waterline)
Fill with water (approx. 3 to 4 liters).
Coolant circuit
If engine is out of service for more than one year, change coolant
(→ Page 230).
Coolant circuit
Check coolant level (→ Page 228).
Coolant circuit
Heat engine coolant with coolant preheater.
HP fuel pump
Only for engines without oil priming pump
Fill HP fuel pump with fresh engine oil (→ Page 183).
Engine Control System
Switch master switch to ON;
Press illuminated pushbutton READY FOR OPERATION (→ Page 99).
Engine Control Unit ECU
Check plug connections (→ Page 249).
EIM
Check plug connections (→ Page 251).
EMU 8
Check plug connections (→ Page 250).
LOP
Press illuminated pushbutton LAMP TEST (→ Page 99).
100 | Operation | MS150045/03E 2018-08
TIM-ID: 0000010093 - 007