5.10 Engine – Shutdown
Preconditions
☑
Engine is running in Local mode
CAUTION
Shutting down from full-load operation may cause hot water to escape from the expansion tank.
Risk of scalding!
• Allow engine to cool down.
• Wear protective clothing, protective gloves, and safety goggles / safety mask.
NOTICE
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
• Before shutting down, disengage gear and run the engine at idle speed for at least 10 minutes until
engine temperatures have dropped and constant values are displayed.
The engine can be stopped from the following points
Item
Action
Control stand
(→ Operating instructions for electronic system)
Local Operating Panel LOP
(→ Operating instructions for electronic system)
Local Operation Station LOS (→ Operating instructions for electronic system)
CCU
(→ Operating instructions for electronic system)
M015650/06E 2018-05
| Operation | 57
TIM-ID: 0000002298 - 004