3 – 06
Operation
3.6
Stopping the engine in manual mode
Preconditions
• Generator is not connected to network.
• Engine is running in manual mode.
CAUTION
Stopping the engine when it is running at full load causes extreme stress to the engine.
Risk of overheating, damage to components!
• Before stopping the engine, operate it at idle speed until operating temperatures decrease
and stable values are indicated.
Preparation
Item
Task
Engine
After the generator circuit breaker has been opened, allow the engine to cool
down by running it idle for approx. 5 minutes.
Stopping the engine
Item
Task
Switching cabinet, control
panel etc. (depending on
manufacturer)
Press stop button.
• Automatic stopping procedure is performed;
• Engine is stopped.
After stopping the engine
Item
Task
Cooling pump
Operate for approx. 5 minutes after engine stop.
M015560
/
00E 03-05 © MTU
Содержание 12V 2000 G23
Страница 4: ......
Страница 10: ...1 II Table of Contents M015560 00E 03 05 MTU...
Страница 20: ...1 10 Safety M015560 00E 03 05 MTU...
Страница 22: ...2 II Table of Contents M015560 00E 03 05 MTU...
Страница 94: ...3 II Table of Contents M015560 00E 03 05 MTU...
Страница 104: ...3 10 Operation M015560 00E 03 05 MTU...
Страница 106: ...4 II Table of Contents M015560 00E 03 05 MTU...
Страница 120: ...4 14 Maintenance Schedule Application Group 3A M015560 00E 03 05 MTU...
Страница 121: ...Table of Contents 5 I 5 Troubleshooting 5 1 Troubleshooting 5 01 5 2 ECU alarms 5 04 M015560 00E 03 05 MTU...
Страница 122: ...5 II Table of Contents M015560 00E 03 05 MTU...
Страница 199: ...Ventilator Drive 6 59 Final steps 1 Install guard cover 2 Fit screws and tighten M015560 00E 03 05 MTU...
Страница 206: ...6 66 Engine Governor Electronic Control System M015560 00E 03 05 MTU...
Страница 207: ...Table of Contents 7 I 7 Annex 7 1 Abbreviations 7 01 7 2 Index 7 03 M015560 00E 03 05 MTU...
Страница 208: ...7 II Table of Contents M015560 00E 03 05 MTU...