Flashi
ng
code
PID
SID
FMI
Description
Maintenance tasks
13
111
4
Coolant level sensor, input
voltage too low.
1. Check coolant condition
(→ Page 119).
2. Check coolant level, top up if
required (→ Page 112).
3. Check cabling.
4. Contact Service.
13
111
6
Sensor "Top up coolant", in‐
put voltage too low.
1. Check coolant condition
(→ Page 119).
2. Check coolant level, top up if
required (→ Page 112).
3. Check cabling.
4. Contact Service.
14
52
3
Temperature sensor/inter‐
cooler, input voltage too
high.
1. Check cabling.
2. Contact Service.
14
110
3
Coolant temperature sen‐
sor, input voltage too high.
1. Check cabling.
2. Contact Service.
14
175
3
Oil temperature sensor, in‐
put voltage too high.
Contact Service.
15
52
4
Temperature sensor/inter‐
cooler, input voltage too
low.
1. Check cabling.
2. Contact Service.
15
110
4
Coolant temperature sen‐
sor, input voltage too low.
1. Check cabling.
2. Contact Service.
15
175
4
Oil temperature sensor, in‐
put voltage too low.
Contact Service.
16
111
3
Coolant level sensor, input
voltage too high.
1. Check coolant condition
(→ Page 119).
2. Check coolant level, top up if
required (→ Page 112).
3. Check cooler for dirt.
4. Check cabling.
5. Contact Service.
16
111
5
Sensor "Top up coolant", in‐
put voltage too high.
1. Check cabling.
2. Contact Service.
17
51
3
Throttle sensor, input volt‐
age too high.
1. Check cabling.
2. Contact Service.
17
72
3
Blower bypass position, in‐
put voltage too high.
1. Check cabling.
2. Contact Service.
17
354
3
Humidity sensor, electric
circuit defective / high (ver‐
sion 33.0 or later).
1. Check cabling.
2. Contact Service.
54 | Troubleshooting | MS150049/02E 2012-11