Monitoring:
• Exhaust gas temperature, A side
• Exhaust temperature, B-side
• Engine speed
• Oil pressure
• Differential oil pressure
• Coolant temperature
• Coolant level
• Exhaust turbocharger speed
• Leak fuel level
• Oil temperature
• Coolant pressure
• Fuel pressure after filter
Monitoring in engine room
Engine control and monitoring unit (LOP)
Functions:
• Engine speed, oil pressure and coolant temperature are monitored and displayed
• Integrated safety system
• Integrated Test System
• Redundant CAN bus interface to governor and higher-level control and monitoring system
• 24 V DC supply
SOLAS – Fire protection specifications
Special connections
In case of leakage, the connection types shown above are spray-protected even without a cover and
have been confirmed compliant with SOLAS by GL and DNV.
MS150119/00E 2014-08
| General Information | 29
TIM-ID: 0000002177 - 004