mtts Beluga-V1 Скачать руководство пользователя страница 3

V-0-03-EN

Beluga User manual 

Beluga Ventilator is a standalone ventilator intended to provide positive pressure 

ventilation during resuscitation of infants. The device contains a built-in pump to 

generate positive end-expiratory pressure (PEEP) and Peak Inspiratory Pressure 

(PIP) without necessity of any external air sources. An integrated blender and oxygen 

monitoring function also allows oxygen-rich (>21% O2) air with accurate Fraction of 

inspired oxygen (FiO2) to be safely delivered to the patient.

Introduction 

05

Company Information 

04

MEDICAL TECHNOLOGY TRANSFER AND SERVICES Co., LTD

House No. 26,  Alley 41,  An Duong Vuong Street, Tay Ho District, Hanoi City, Vietnam

 

Tel:  +84 24 3766 6521

Fax: +84 24 3718 8050

Email: [email protected]

www.mtts-asia.com

PROMETEO SRL

Via Mantova 9

38122 Trento

Italy

This user manual is intended for health care professionals.

The Beluga Ventilator is to be operated by qualifi ed personnel only. This 

manual, accessory Directions for Use, all precautionary information, and 

specifi cations should be read before use.

WARNING - a warning statement refers to the conditions when the possibility 

of injury to the patient or user exists if a procedure is not followed correctly.

NOTE - a note statement provides additional information intended to clarify 

points, procedures or instructions.

Содержание Beluga-V1

Страница 1: ...Beluga User manual User Manual Effective date March 2020 Issue Number 00 Version 03 EN Issue Date March 2020 www mtts asia com Beluga ventilator Model Beluga V1...

Страница 2: ...r manual Contents Company Information Introduction Device Description Warnings Setup Operation Alarm System Cleaning Maintenance Speci cations Explanation of Symbols Warranty Policy 04 05 06 09 10 12...

Страница 3: ...GY TRANSFER AND SERVICES Co LTD House No 26 Alley 41 An Duong Vuong Street Tay Ho District Hanoi City Vietnam Tel 84 24 3766 6521 Fax 84 24 3718 8050 Email assistance mtts asia com www mtts asia com P...

Страница 4: ...g battery charging conditions 5 Pressure Measurement Displays Measured Pressure 6 FiO2 Measurement Displays Measured FiO2 7 Setting Button Touch this button to enter Setting screen 8 Lock Button Touch...

Страница 5: ...s or nitrous oxide Do not modify this equipment without authorization of the manufacturer Using the device outside of the speci ed ambient temperature range 19 C to 37 C or humidity range 30 RH to 90...

Страница 6: ...device and then directly into the power outlet in the wall B Press the Power Button to turn the device ON Only use T piece circuit and power supply unit provided by MTTS The gas sources must provide p...

Страница 7: ...s B FiO2 Select FiO2 Setpoint circle then touch Up Down button to adjust FiO2 A PIP Select PIP setpoint circle then touch and hold Up Down button to adjust PIP The red horizontal level will move up do...

Страница 8: ...s some features of the device to be con gured To enter Setting screen touch Setting button on the unlocked screen To return the unlocked screen touch the Return button on the Setting screen Resuscitat...

Страница 9: ...ation Oxygen sensor must be calibrated at least every 3 months It is recommended to calibrate the sensor before each use Operation Turning off the device 17 The device can be turned off by Power butto...

Страница 10: ...al and national guidelines for product cleaning fre quencies Ensure oxygen supply is turned off and disconnected from Beluga Ventialator before performing cleaning procedures Cleaning shall be perform...

Страница 11: ...f parts that must be replaced or serviced during the lifetime of the device These parts include Component Approx Duration of Use Maintenance Information Air lter 6 months Clean or replace Oxygen senso...

Страница 12: ...er characteristics Off the shelf external power supply Battery 60W 100 240VAC 47 63Hz International medical safety approvals ANSI AAMI EN 60601 1 UL TUV Class I construction is standard ground require...

Страница 13: ...cturer Date of manufacture Keep out of direct sunlight This device should be disposed of separately from normal household waste so that components can be recycled Refer to User Manual before operating...

Страница 14: ...ew materials and used materials equivalent to new in performance and reliability MTTS may repair or replace MTTS products a with new or previously used products or parts equivalent to new in performan...

Страница 15: ...all software patches run MTTS diagnostics and utilities Implement temporary procedures or workarounds provided by MTTS while MTTS works on permanent solution Cooperate with MTTS in attempting to resol...

Страница 16: ...D SERVICES Co LTD House No 26 Alley 41 An Duong Vuong Street Tay Ho District Hanoi City Vietnam Tel 84 24 3766 6521 Fax 84 24 3718 8050 Email assistance mtts asia com www mtts asia com PROMETEO SRL Vi...

Отзывы: