5
Specifications
Parameter
Specification
Operating Environment:
Temperature
Humidity
0 to 45°C (32 to 113°F) Maximum, Ambient
0 to 95% noncondensing
Input/Output Interface:
Analog Signals
Velocity Command Input
Auxiliary Input
Velocity Output
Current Output
Differential input 0 to ±10 Vdc(15 Vdc Max)
Differential input 0 to ±10 Vdc(15 Vdc Max)
1.5 volts per 1000 rpm (default)
±10 volts = ± Peak Current
24 Volt Logic:
Reset
+ Limit
- Limit
Velocity/Torque Select
Fault Output(Open Collector)
Overspeed
Fault Protection:
Continuous Current
Shorts(Stator)
Amplifier Temperature
Feedback Resolver Wiring
Motor Thermal
HI-BUS
Overspeed
Encoder Simulation:
TTL Differential Output Plus Index
Phase Quadrature
Line Count(select with DIP switch);
Standard - 250, 360, 400, 500, 720, 1000, 1024, 2000, and
4096
Electrical Characteristics:
Input Voltage
200 to 520 Vac
45 to 65 Hz
Single or Three Phase
No Isolation Transformer Required
Output Characteristics
(All Models)
Quasi Trapezoid with Torque Linearization
Torque Ripple 5% Maximum
MPA-05-460:
Output:
Input:
5 amps continuous; 10 amps peak; peak
≤
1 second
PWM frequency 15 kHz
Single phase; 6 amps continuous max
Three phase; 4 amps continuous max
DC Bus is AC line dependent
MPA-09-460:
Output:
Input:
9 amps continuous; 18 amps peak; peak
≤
1 second
PWM frequency 15 kHz
Single phase, 9 amps continuous max
Three phase; 11 amps continuous max
DC Bus is AC line dependent
Содержание MPA-05-460
Страница 12: ...12 ANF3 User Configuration Locations NOTE Never change DIP switches or jumpers with power ON...
Страница 35: ...35 Shunt Amplifier Wiring...
Страница 36: ...36 EXS 50 100 460 Mechanical Footprint 0 5 6 16 0 15 5 0 5 0 0 1 0 8 5 9 5...
Страница 38: ...38 Inductor Mechanical Footprint loose parts Typical IND 100 5mH 5 25 4 81 44 0 0 42 3 85 4 27 6 35 0...
Страница 39: ...39 Typical IND 25 460 2mH 4 60 0 3 39 3 10 29 0 0 25 3 05 3 30 20 3 75 Clearance...
Страница 41: ...41 Typical S Three Phase 460V Amplifiers...
Страница 45: ...45 Typical Wiring...