16
JP19
SPINDLE ORIENT ENABLE
disabled
enabled
(STANDARD)
The position of this jumper determines whether the shaft will turn at 1 rps when PIN 13 is
grounded.
JP11
ORIENT DIRECTION
CW (viewed from shaft end)
CCW
(STANDARD)
The position of this jumper determines which direction the motor will turn when the orient
feature is enabled.
JP9
RESETABLE
FAULTS
(STANDARD)
NON
RESETABLE
FAULTS
When JP9 is in the left position (default) the amplifier must be power cycled to reset any faults.
In the right position, the faults can be cleared with the reset button or by toggling the enable
input.
Spindle Ramp Times
DIP 1 Switch Settings (0 = off, 1 = on)
1
2
3
4
TIME (sec)
0
0
0
0
2.00
1
0
0
0
3.00
0
1
0
0
3.45
1
1
0
0
4.00
0
0
1
0
5.20
1
0
1
0
5.40
0
1
1
0
5.90
1
1
1
0
6.10
0
0
0
1
8.00
1
0
0
1
8.20
0
1
0
1
8.80
1
1
0
1
9.00
0
0
1
1
9.40
1
0
1
1
9.75
0
1
1
1
10.10
1
1
1
1
10.40