Parameter
Specification
Motor Inductance:
230 Volt Amplifiers:
460 Volt Amplifiers:
For all 230 volt products, the inductance line to line must be
no less than 2mH.
For all 460 volt products, the inductance line to line must be
no less than 4mH. The turn ON times of the power switches
can cause catastrophic destruction of motors. Inductors in
RST of the motor leads limit the rise time and preserve the
motor. All 460 volt motors must have inductors.
Note: The parallel delta connection usually requires added
inductors. The following inductors are available:
IND-100-.5mH
IND-25-460-2mH
One inductor in each line is typical.