14
The location of these adjustments is directly below the I/O wiring.
NOTE
The pot labeled AUX controls the speed of
the spindle orient feature and need not be
adjusted by the user.
FEEDBACK AND I/O CONTROL ASSEMBLY
AUX
SIG
RESP
CUR
BAL
RESET
ENCODER
I/O
GND
ORIENT
RAMPS
GND
-COM
+COM
CUR
TAC
GND
FLT
SHFT
SLOW
SPD
ENB
Outputs
Two diagnostic outputs are the dc voltage proportional to velocity and the dc output
proportional to current/torque. The nominal TAC gradient changes based on the selected
speed ranges of 1200, 2400 and 4200 rpm, and is ±1 volt per 1000 rpm. The current gradient
is 10 volts equals the continuous rating.