Temposonics
®
E-Series CANopen
Operation Manual
4
2.1 Intended use
This product may be used only for the applications defined under
item 1 in conjunction with the third-party devices and components
recommended or approved by MTS Sensors. As a prerequsite of
proper and safe operation, the product requires correct transport,
storage, mounting and commissioning and must be operated with
utmost care.
1.
The sensor systems of all Temposonics
®
series are intended
exclusively for measurement tasks encountered in industrial,
commercial and laboratory applications. The sensors are
considered as system accessories and must be connected to
suitable evaluation electronics, e.g. a PLC, IPC, indicator or other
electronic control unit.
2. Safety instructions
Forseeable misuse
Consequence
Wrong sensor connection
The sensor does not work
properly or will be destroyed
Operate the sensor out off the
operating temperature
No signal output
The sensor can be damaged
Power supply is out of the
defi ned range
Signal output is wrong /
no signal output /
the sensor will be damaged
Position measurement is
infl uenced by an external
magnetic fi eld
Signal output is wrong
Cables are damaged
Short circuit – the sensor can
be destroyed / sensor does not
respond
Spacers are missing /
are installed in a wrong order
Error in position measurement
Wrong connection
of ground / shield
Signal output is disturbed
The electronics can be damaged
Use of a magnet that is not
certifi ed by MTS Sensors
Error in position measurement
Do not reprocess the sensor afterwards.
The sensor might be damaged.
Do not step on the sensor.
The sensor might be damaged.
2.2 Forseeable misuse