background image

         

temperature  measurements,  some  time  (several 
minutes) is required after the low (and before the high) 
temperature measurements are made. 
This is a result of the cooling process, which must take 
place for the IR sensor. 
 

4.  BATTERY REPLACEMENT 

  As battery power is   

not sufficient, LCD   

will display “        ” 
replacement with one   
new battery type 9V is required. 

     

  Open battery cover, then take   

out the battery from instrument   
and replace with a new 9-Volt   
battery and place the battery cover back.       
 

 

6

NOTES:       

 

How it Works 

Infrared 

thermometers 

measure 

the 

surface 

temperature  of  an  object.  The  unit’s  optics  sense 
emitted,  reflected,  and  transmitted  energy,  which  is 
collected  and  focused  onto  a  detector.  The  unit’s 
electronics translate the information into a temperature 
reading,  which  is  display  on  the  unit.  In  units  with  a 
laser, the laser is used for aiming purposes only. 
 
 

Open the battery over

9v battery

Low battery indicator

www.

.com

[email protected]

1.800.561.8187

Содержание MTP-1325

Страница 1: ...MTP Operating Manual Model MTP 1325 Non Contact Infrared Thermometers 5 8 7p 9 12 11p 1 4 3p 6p 5p 9p 10p MTP Instruments www com information itm com 1 800 561 8187...

Страница 2: ...ON 3 FEATURES 3 WIDERANGEAPPLICATION 3 SAFETY 4 DISTANCE SPOTSIZE 4 SPECIFICATIONS 5 FRONTPANELDESCRIPTION 6 INDICATOR 6 MEASURMENTOPERATION 7 BATTERYREPLACEMENT 8 NOTES 8 MAINTENANCE 11 www com infor...

Страница 3: ...such as moving object the surface with electricity current or the objects which are uneasy to be touched Proper use and care of this meter will provide years of reliable service FEATURES Rapid detecti...

Страница 4: ...the laser light beam impinge on any gas which can explode Distance Spot Size As the distance D from the object increases the spot size S of the area measured by the unit becomes larger The relationsh...

Страница 5: ...F 0 5 or 0 5 C 0 9 F Response time 150ms Spectral response 8 14um Emissivity Fixed at 0 95 Over range indication LCD will show Polarity Automatic no indication for positive polarity Minus sign for ne...

Страница 6: ...target is at least twice as large as the spot size 2 FRONT PANEL DESCRIPTION IR sensor LCD Display Laser pointer beam Measurement Trigger Battery Cover Handle Grip 3 INDICATOR Data hold Laser on symb...

Страница 7: ...battery if the display does not light Release the Trigger and the HOLD display icon will appear on the LCD indicating that the reading is being held The meter will automatically power down after appro...

Страница 8: ...ut the battery from instrument and replace with a new 9 Volt battery and place the battery cover back 6 NOTES How it Works Infrared thermometers measure the surface temperature of an object The unit s...

Страница 9: ...ate hot spot Reminders Not recommended for use in measuring shiny or polished metal surfaces stainless steel aluminum etc See Emissivity The unit cannot measure through transparent surfaces such as gl...

Страница 10: ...Cloth black 0 98 Concrete 0 94 Human skin 0 98 Cement 0 96 Lather 0 75 to 0 80 Sand 0 90 Charcoal powder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to...

Страница 11: ...manual and should only be carried out by qualified trained technician Periodically wipe the body with a dry cloth Do not use abrasives or solvents on this instrument For service use only manufacturer...

Страница 12: ...ge Social 4409 rue Charleroi Montr al Nord Qu bec H1H 1T6 T l phone 514 326 7167 T l copieur 514 326 7835 Ligne directe 1 888 326 7167 Site Web www mtpinc com Courrier lectronique info mtpinc com www...

Отзывы: