background image

model 

MP25 

M25 

MP35 

M35 

MP50 

M50 

MP65 

M65 

MP80 

M80 

MP100  M100  MP125  M125  MP150

Gross 

thermal 

heat cap.

 

Kcal/h 

kW 

28,000 

32.6 

28,000 

32.6 

38,700 

45 

38,700 

45 

56,000 

65.1 

56,000 

65.1 

72,000 

83.7 

72,000 

83.7 

90,000 

104.7 

90,000 

104.7

 

110,600 

128.6 

110,600 

128.6 

141,500 

164.5 

141,500 

164.5 

165,200 

192.1

Net 

thermal 

heat cap.

 

Kcal/h 

kW 

25,508 

29.7 

25,508 

29.7 

35,000 

40.7 

35,000 

40.7 

51,016 

59.3 

51,016 

59.3 

65,000 

75.6 

65,000 

75.6 

82,000 

95.3 

82,000 

95.3

 

100,000 

116.3 

100,000 

116.3 

128,057 

148.9 

128,057 

148.9 

149,000 

173.3

Efficienc

y

 

91.1 

91.1 

90.4 

90.4 

91.1 

91.1 

90.3 

90.3 

91.2 

91.2 

90.4 

90.4 

90.5 

90.5 

90.2

Comb. 

chamber 

resist.

 

mbar 

0.2 

0.2 

0.22 

0.22 

0.2 

0.2 

0.22 

0.22 

0.23 

0.23 

0.25 

0.25 

0.2 

0.2 

0.25

Comb. 

chamber 

vol.

 

m

3

 

0.05 

0.05 

0.05 

0.05 

0.17 

0.17 

0.17 

0.17 

0.24 

0.24 

0.24 

0.24 

0.33 

0.33 

0.33

Volume 

m

3

 

0.08 

0.08 

0.08 

0.08 

0.22 

0.22 

0.22 

0.22 

0.32 

0.32 

0.32 

0.32 

0.46 

0.46 

0.46

Mean 

exhaust 

gas 

temp. 

°C 

195 

195 

228 

228 

196 

196 

229 

229 

196 

196 

228 

228 

229 

229 

241

Fuel 

cons. 

l/h 

1.8 - 

3.0 

2.1 - 

3.3 

3.5 - 

3.9 

3.5 - 

3.9 

4.0 - 

6.4 

4.0 - 

6.4 

5.8 - 

8.0 

5.8 - 

8.0 

7.9 - 

9.8 

7.9 - 

9.8 

9.7 - 
12.5 

9.7 - 
12.5 

12.5 - 

16.0 

12.5 - 

16.0 

16.5 - 

19.0

Air 

output 

m

3

/h 

2170 

2100 * 

2860 

2800 * 

4100 

4700 **  4740 

5800 **  6300 

8800 

*** 

7420 

11800 

*** 

10000  13000 

*** 

13900

Air flow 

(m

3

/h) 

in ducts 

at 

resist. 

(Pa) 

m

3

/h 

Pa 

1950 

60 

no data  2750 

50 

no data  3600 

150 

no data  4500 

200 

no data  6000 

100 

no data  7300 

100 

no data  9700 

200 

no data  12400 

200

Fan 

motor 

power 

122 

150 

247 

150 

373 

420 

550 

420 

1100 

830 

1100 

830 

5700 

880 

9000

Max. 

motor 

power 

cons. 

1.3 

0.7 

2.23 

0.7 

4.15 

1.85 

5.3 

1.85 

7.1 

1.6 

7.3 

1.6 

9.2 

1.8 

14.5

Noise 

level 

db (A) 

61 

59 

62 

59 

71 

65 

72 

65 

71 

68 

72 

68 

73 

70 

73

* DO NOT CONNECT TO DUCTS
** OPTION OF TRANSPORT OF AIR UP TO 5 R. M.
** OPTION OF TRANSPORT OF AIR UP TO 10 R. M.

Содержание MP25

Страница 1: ...AIR HEATER UNIT TYPES M MP Original instruction manual v 08 2015 ...

Страница 2: ...ssment of human responses to contact with surfaces Hot surfaces EN ISO 13857 2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs EN ISO 14159 2008 Safety of machinery Hygiene requirements for the design of machinery EN 60335 1 2002 A14 2010 Household and similar electrical appliances Safety General requirements EN 55014 1 2006 A1 2009 Electromag...

Страница 3: ... it Failure to observe remarks indicated with this symbol may lead to damage to the heater or even to personal injury IMPORTANT This is an indication of the requirement to read the information found after it very carefully as this will contribute to safe use of the device 1 3 General indications Air heaters with heat exchangers may be used in rooms in which people remain WARNING Never install the ...

Страница 4: ... casing is made of painted sheet steel and possesses a thermal insulation layer made of non flammable insulation wool with an aluminium layer Under the combustion chamber in the ventilation part there is the ventilator The ventilation chamber is protected by a mesh Furthermore the heater is equipped with the following safety devices ventilator thermostat automatically switches the ventilator on an...

Страница 5: ...lator may turn on again this does not indicate of a flaw In order to shut down the entire heater set the main switch to position 0 4 3 LIMIT 2 safety thermostat When the air temperature exceeds 80 C the Limit thermostat shall shut down the burner and later it will turn it on again automatically If the thermostat does not operate properly and if the air temperature rises to 100 C the main safety th...

Страница 6: ...vice safety thermostat MV fan TA room thermostat F1 fan fuse F2 burner fuse 400 V supply version IG main switch M fan TV FUN fan thermostat 35 C TLR contactor RT thermal relay BR burner TS overheat thermostat 110 C TSS burner shutdown thermostat 80 C TP room thermostat L coil FO fuse INT device function switch SR power supply diode STV fan failure diode STS overheat diode ...

Страница 7: ...he burner A B C D E Weight kg mm mm mm mm mm MP25 1440 530 660 1225 150 140 M25 130 MP35 148 M35 130 MP50 1650 640 870 1390 180 210 M50 138 MP65 220 M65 200 MP80 1800 750 1000 1525 200 315 M80 210 MP100 325 M100 305 MP125 2020 800 1230 1760 250 480 M125 450 MP150 490 9 Sample nameplate on the back housing of the device ...

Страница 8: ... 17 0 17 0 24 0 24 0 24 0 24 0 33 0 33 0 33 Volume m3 0 08 0 08 0 08 0 08 0 22 0 22 0 22 0 22 0 32 0 32 0 32 0 32 0 46 0 46 0 46 Mean exhaust gas temp C 195 195 228 228 196 196 229 229 196 196 228 228 229 229 241 Fuel cons l h 1 8 3 0 2 1 3 3 3 5 3 9 3 5 3 9 4 0 6 4 4 0 6 4 5 8 8 0 5 8 8 0 7 9 9 8 7 9 9 8 9 7 12 5 9 7 12 5 12 5 16 0 12 5 16 0 16 5 19 0 Air output m3 h 2170 2100 2860 2800 4100 4700...

Отзывы: