background image

7

INM9469-3

June 2012

Security

64/128 bits WEP, WPA-PSK, WPA2-PSK, IEEE 802.11x (RADIUS) authentication, MAC address 
filtering, SSID broadcast control.

Modes

Access Point (AP) for WiFi Network Infrastructure, Bridge mode to connect any 10/100 wired 
Ethernet equipment to a wireless network, Repeater (WDS) mode to extend wireless coverage, 
Infrastructure & AD-HOC modes are supported.

Administration

Built-in Web interface. Setup of the device using a web browser.

14  ACCESSORIES

For interconnecting the 9460-ET range of products, we offer approved RJ45 Cat5e UTP cables in 
various standard lengths (0.5…100m).

The ANTSMA94 omnidirectional antenna is ideal for use where good general coverage is required.

Ordering details

Copper Twisted Pair UTP Patch Cable (Blue) pre-terminated RJ45-RJ45 connectors
Part No. CSL9405-xx 

( -xx is used to signify the length of the cable.)

Part No. ANTSMA94  

Omnidirectional antenna

15  APPROVALS

The operating parameters must not exceed those as detailed on the certificate.

 

2004/108/EC  EMC Directive

 

2006/95/EC 

Low Voltage Directive

Region

Europe (ATEX)

International IECEx

USA

Canada

Authority

SIRA

SIRA

FM

FMC

Standard

EN 60079-0: 2006, 

EN 60079-11: 2007,

IEC 60079-26: 2006, 

EN 50303: 2000,

IEC 61241-0: 2004,

IEC 61241-11: 2005

IEC 60079-0: 2004,

IEC 60079-11: 2006,

IEC 61241-0: 2004,

IEC 61241-1: 2005

3600: 1998 

3610: 2007 

3810: 2005

C22.2 No. 61010.1: 2004

C22.2 No. 157: 1992

CAN/CSA-E60079-0: 

2007

CAN/CSA-E60079-11: 

2002

Approved for E I M1 

E II 1GD 

Ma Ex ia I 

Ga Ex ia IIC T4 

Ex iaD 20 T135°C  

(Ta = –40˚C to +60˚C)*

Ma Ex ia I 

Ga Ex ia IIC T4 

Ex iaD 20 T135°C 

(Ta = –40˚C to 

+60˚C)§

IS/I/1/ABCD/T4 Ta=60°C

I/0/AEx ia IIC T4 

Ta=60°C

IS/I/1/ABCD/T4 Ta=60°C

I/0/Ex ia IIC T4 Ta=60°C

Cert. no.

Sira 07ATEX2064X

IECEx SIR 07.0042X

3034995

3034995C

                            * (see specification for operating temperature range)

16  FM CERTIFICATION INFORMATION

Special Condition of Use - Factory Mutual (USA & Canada)

 

The Model 9469-ETplus shall be installed in compliance with the enclosure, mounting, spacing 
and segregation requirements of the ultimate application.

 

The Model 9469-ETplus shall be excluded from use in environments containing chemical 
vapours of the Ketone or Ester families.

Содержание 9469-ETplus

Страница 1: ...Instruction Manual INM9469 9469 ETplus 108Mbps Wireless Bridge Access Point ...

Страница 2: ...ii INM9469 3 June 2012 ...

Страница 3: ...Collect Network Parameters 4 5 LOCATING ON THE NETWORK 4 6 WEB CONFIGURATION 5 7 SWITCHING BETWEEN ACCESS POINT AND BRIDGE 5 8 DEVICE CONFIGURATION 5 9 UPGRADE 5 10 MAINTENANCE TROUBLESHOOTING 6 11 ENVIRONMENTAL 6 12 WASTE REMOVAL INFORMATION 6 13 TECHNICAL 6 14 ACCESSORIES 7 15 APPROVALS 7 16 FM CERTIFICATION INFORMATION 7 17 ATEX IECEX CERTIFICATION INFORMATION 8 Measurement Technology Limited 2...

Страница 4: ...iv INM9469 3 June 2012 ...

Страница 5: ...nd Wireless Repeater WDS Modes of Operation Easy web based configuration Status LED s For Power On WLAN Activity Status Mode Copper UTP Activity Copper UTP 10 100Mb Link DIN rail mounting module Note PoEx is a simple adaptation of the IEEE 802 3af Power over Ethernet PoE standard to bring the benefits to the 9400 Range of Hazardous Area devices This allows two spare pairs in the existing Cat5e cab...

Страница 6: ...ompetent personnel and in accordance with all appropriate international national and local standard codes of practice and site regulation for intrinsically safe apparatus and in accordance with the instructions contained here See also Sections 14 15 16 for approvals and important conditions of safe use 3 1 Protection The module requires mounting within an enclosure providing a degree of protection...

Страница 7: ...crew terminals 1 to 4 see above 1 RX 2 RX 3 TX 4 Supply 12V PoEx 5 Supply 12V PoEx 6 TX 7 Supply 0V PoEx 8 Supply 0V PoEx When connecting the Cat5e cable to another device a straight connected RJ45 cable is used a crossover cable is not required as the RJ45 connector performs the crossover It is recommended that Cat5e cables for Hazardous Area Zone 1 use are Blue in colour and are of good quality ...

Страница 8: ... communicate with other equipment It is recommended to use less than 3 channels in the same covered area in order to avoid disturbances It is also recommended to leave at least two unused channels between each radio channel In Ad hoc mode all the equipment must have the same radio channel Legislation is different in each country check what channels you can use in the country where the device is in...

Страница 9: ...ACCESS POINT AND BRIDGE To change the operating mode enter the menu BASIC WIRELESS and choose the firmware you want to use Then click on Save Settings and Reboot the Device The device will then restart and use the selected firmware 8 DEVICE CONFIGURATION The administration pages consist of the following five categories Basic Configure IP addresses 802 11 mode radio channel SSID security Advanced C...

Страница 10: ...s product is disposed of correctly you will be helping to prevent potentially negative consequences for the environment and human health which could otherwise be caused by incorrect waste handling of this product For more detailed information about the take back and recycling contact MTL 13 TECHNICAL Ethernet LAN RJ45 10 100 Base TX Interface WiFi IEEE 802 11a b g h 2 4 5 5 4 GHz standards multi c...

Страница 11: ...the certificate 2004 108 EC EMC Directive 2006 95 EC Low Voltage Directive Region Europe ATEX International IECEx USA Canada Authority SIRA SIRA FM FMC Standard EN 60079 0 2006 EN 60079 11 2007 IEC 60079 26 2006 EN 50303 2000 IEC 61241 0 2004 IEC 61241 11 2005 IEC 60079 0 2004 IEC 60079 11 2006 IEC 61241 0 2004 IEC 61241 1 2005 3600 1998 3610 2007 3810 2005 C22 2 No 61010 1 2004 C22 2 No 157 1992 ...

Страница 12: ...e dust moisture and other contaminants c This equipment is intrinsically safe electrical apparatus and is normally mounted in a hazardous area When mounted in a Zone1 location the apparatus must be provided with an enclosure which offers an additional degree of protection appropriate to the area classification Read also the Special Conditions for Safe Use for any additional or more specific inform...

Страница 13: ...9 INM9469 3 June 2012 ...

Страница 14: ...e Cc cable Co psu Ci app Lc cable Lo psu Li app L R cable Lo Ro psu 12VDC IS Power Supply 9469 WLAN AP Bridge PoEx Supply for Port 3 Device Supply for 9466 PoEx for 9461 via Port 3 Supply for 9466 PoEx for 9465 via Port 5 Supply for 9465 PoEx not used Supply for 9466 PoEx Supply for Port 5 Device Supply for 9469 PoEx Supply for Port 1 Device PoEx Supply for Port 3 Device No PoEx No PoEx PoEx for 9...

Страница 15: ...ing of Typical Installation SIZE DWG NO REV A3 9400 System 4 SCALE SHEET 2 OF 2 CSL SCALE TITLE H G F E D C B A 8 7 6 5 4 3 2 1 H G F E D C B A 8 7 6 5 4 3 2 1 NOTE RJ45 ETHERNET PORTS ARE INTENDED FOR CONNECTION ONLY TO OTHER 9400 SERIES MODULES SHOWN ON THIS DRAWING With the exception of 9468 ET Safe Area port ...

Страница 16: ...02011 Fax 39 0 2 61294560 E mail info mtl inst it Cooper Crouse Hinds Japan KK MT Building 3F 2 7 5 Shiba Daimon Minato ku Tokyo Japan 105 0012 Tel 81 0 3 6430 3128 Fax 81 0 3 6430 3129 E mail info cooperindustries jp Cooper Crouse Hinds Korea 12F Vision Tower 707 2 Yeoksam dong Gangnam gu Seoul 135 080 South Korea Tel 82 2 3484 6795 Fax 82 2 3484 6778 E mail MTLKorea enquiry cooperindustries com ...

Отзывы: