![MTD 61 series Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/mtd/61-series/61-series_shop-manual_1850092095.webp)
Ignition System
89
10.
Resistance in the primary windings of the ignition
module, measured between the spade terminal and
the laminations, was observed to be in the 550-650
10a. Resistance in the secondary windings of the
ignition module, measured between the spark
plug terminal and the laminations, was
observed to be in the 8K-9K
range. See
NOTE:
There may be slight variation in specification due
to production variation and other factors such as
temperature.
• Resistance figures that are vastly lower may indi-
cate a short in the windings being tested.
• Resistance figures that are vastly higher (or O.L)
may indicate a fault in the windings being tested.