Red 

The indicator is unused on 
PSE-S+. 

Off 

No power supplied. 

 
 
*SWITCH LED (the right indicator on RJ45) 

  LED 

STATUS 

Description 

P1~P8 
Link/Act 
     
 
 
 
 

Green 

 

A network device is detected (1000Mbps), 
but no communication activity is detected. 
 

Green 
Blinking 

 

This port is transmitting to, or receiving 
package from another device at 1000Mbps. 
 

Yellow 

A network device is detected (10Mbps or 
100Mbps), but no communication activity 
is detected. 
 

Yellow 
Blinking 
 

 

This port is transmitting to, or receiving 
package from another device at 10Mbps or 
100Mbps. 

Off 

No device is detected. 

 
  *PoE LED (the left indicator on RJ45) 
 

P1~P7   
PoE 
 
 
 

Yellow 

 

 

A valid Powered Device (PD) is detected 
and delivering power on this port. 

    Off 
 

No PD is detected on this port. 
 

UPLINK (P8) 
PoE 

Yellow                 

 

PSE-S+ unused 

    Off 

No power is detected on this port. 

 

Содержание PSE-SW8G44D0++

Страница 1: ...USER S MANUAL MSTRONIC CO LTD PSE SW8G44D0 8 Port PoE Switch...

Страница 2: ...livers power up to 70W port to a PD The LTPoE is Linear Technology Corporation s specification This specification provides detection and classification extensions to existing IEEE PoE protocols It is...

Страница 3: ...or receiving package from another device at 1000Mbps Yellow A network device is detected 10Mbps or 100Mbps but no communication activity is detected Yellow Blinking This port is transmitting to or re...

Страница 4: ...for 802 3at operation The input voltage must be in the range of 55 to 57VDC if using for LTPoE operation If the PoE switch is not powered with the above designated input voltage it will only function...

Страница 5: ...tches hubs or workstations etc without regard to using straight through or crossover cabling Port 1 to 7 provides Power over Ethernet function that delivers DC power through the data pairs mode A mode...

Страница 6: ...ect the other side to your attached device The Link Act LED green or yellow will light up when the cable is correctly connected Refer to the LED Indicator section for descriptions of each LED indicato...

Страница 7: ...e B All 1 Negative Vport Positive Vport 2 Negative Vport Positive Vport 3 Positive Vport Negative port 4 Positive Vport 5 Positive Vport 6 Positive Vport NegativeVport 7 Negative Vport 8 Negative Vpor...

Страница 8: ...Protocols CSMA CD Flow control IEEE802 3x full duplex back pressure half duplex Data transmission rate 1488000pps for1000base T 148800pps for 100base T 14880pps for 10base T Address table 8K MAC addre...

Страница 9: ...ing 10M 100Mbps PoE Yellow port 1 7 ON PD detect Port 8 unused Power input DC power supply on rear terminal IEEE802 3af 44V 57V IEEE802 3at 51V 57V LTPoE 55V 57V Power consumption less 5W without PD l...

Отзывы: