MSTRONIC PSE-SW8 series Скачать руководство пользователя страница 1

 
 

 

 

 

 

 

 

 

 

 

 

PSE-SW8 series 

8 Port PoE Switch (Endspan) 

(Extend Ethernet and PoE) 

USER’S MANUAL 

 

MSTRONIC CO., LTD.

 

Содержание PSE-SW8 series

Страница 1: ...PSE SW8 series 8 Port PoE Switch Endspan Extend Ethernet and PoE USER S MANUAL MSTRONIC CO LTD...

Страница 2: ...SE SW8 Series MSTRONIC CO LTD 2 1 General Information 2 Hardware Description LED Indicators Power Wiring Ethernet Port PD Port Wiring 3 Network Application 4 Model Information 5 Technical Specificatio...

Страница 3: ...ut voltage is equal to the input voltage The PoE Switch can be used as an Ethernet PoE repeater to extend Ethernet data and DC power up to 200 meters This manual will help you install and maintain the...

Страница 4: ...t 2A The indicator is unused on PSE SW8D Off No power in DC input SWITCH indicator the right LED on RJ45 LED STATUS Description P1 P8 Link Act Green A network device is detected at 100Mbps but no comm...

Страница 5: ...ximum for temporary but total output power MUST limited at 7A maximum If power input from port 8 the input current is limited at 2A maximum the output is 0 25A port For PSE SW8D The input voltage must...

Страница 6: ...t you can use an AC DC adapter with DIN 4P connector directly recommends adaptor as detailed below OPTION MS 180 18 MS 180 24 MS 180 56 Maximum output 18VDC 8 33A 24VDC 6 25A 56VDC 3 21A Related model...

Страница 7: ...t the opposite end Straight through Cabling Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 6 Pin 6 Cross over Cabling Pin 1 Pin 3 Pin 2 Pin 6 Pin 3 Pin 1 Pin 6 Pin 2 Connect an Ethernet cable into any switch...

Страница 8: ...o the PD It will power 802 3af compliant devices if it is powered at 48VDC although it will not perform the 802 3af handshake with the client device The PoE Switch can be installed in a more appropria...

Страница 9: ...3at compliant 12 57VDC 12 57VDC Higher input voltage As input voltage non regulated non 802 3at compliant PSE SW8D 44 57VDC No input 44 57VDC As input voltage non regulated 802 3at compliant No input...

Страница 10: ...3x full duplex back pressure half duplex Data transmission rate 148800pps for 100base T 14880pps for 10base T Address table 2K MAC address table self learning Connect RJ 45 PoE port Port 1 7 Pin assi...

Страница 11: ...d alarm Power input DC 12V 57V from rear panel or DC 44V 57V from port 8 from midspan or network switch Power consumption 5W when without PD loading Input Voltage Input Current 12V 0 058A 24V 0 037A 4...

Страница 12: ...e Data 16 5V I PP 5A t p 8 20 s I O pin to GND Peak Pulse Current 20A tp 8 20 s Pin Protected 4 pin protected signal pairs Max Shut Capacitance 3pF VR 0V f 1MHz I O pin to GND 1 5 pF VR 0V f 1MHz Betw...

Отзывы: