MSI xDAP Скачать руководство пользователя страница 7

4. Mounting and Environment

There are typically no  thermal hazards when desktop equipment is used as intended and with reasonable care on the 
desktop.

Rack mounted systems will need to provide clearance sufficient for the power cord connector, so that there is no danger of  
crimping and damaging the power conductors to create a risk of short circuits and fire.

If there is an external enclosure into which an xDAP unit is mounted, there must be sufficient separation between the 
enclosure door and xDAP front panel to avoid damaging front panel cables and connectors. Some separation might be  
needed between the enclosure's door and cables to avoid coupling of electrical ground noise into sensitive signal paths. 

The   processor   chip  inside  of  the  xDAP  unit  will  generate   a  significant  amount  of  heat.  The  maximum  safe  ambient 
temperature   is   given   in  the   technical   specifications,   but   will   typically  be   around   50   degrees   Centigrade.   In   general, 
temperatures that are safe for humans are also safe for operating the xDAP units, but sustained operation at relatively high  
ambient   temperatures   could   accelerate   degradation   of   materials   in  electronic   components,   thus  impairing  the   product 
lifetime. 

For equipment mounted in an enclosure, there must be adequate air flow to carry away generated  heat and avoid an 
excessive temperature rise inside of the enclosure. The air intake is through the bottom plate. The primary fan for drawing 
air and processor heat out of the unit is on the back of the xDAP unit. It is particularly important that these air flow paths are 
not obstructed. 

If it is necessary to unmount the unit, the recommended sequence of actions is:

1. stop software processing first if you can

2. turn off the front panel illuminated switch

3. turn off the back panel power supply switch

4. disconnect the power cable

The unit is not isolated from environmental hazards. Take appropriate precautions to prevent liquids and other contaminants 
from getting into the equipment and causing harm to sensitive electronic components.

7

Содержание xDAP

Страница 1: ...xDAP Family Safety Manual Safety Guidelines and Declaration of Conformity for the xDAP Family Version 1 01 Microstar Laboratories Inc...

Страница 2: ...oratories Inc Microstar Laboratories Inc 2265 116th Avenue N E Bellevue WA 98004 Tel 425 453 2345 Fax 425 453 3199 www mstarlabs com Data Acquisition Processor DAP and xDAP are trademarks of Microstar...

Страница 3: ...Contents 1 Introduction 4 2 Products Covered 5 3 Specifications 6 4 Mounting and Environment 7 5 Electrical Grounding 8 6 Access and Maintenance 9 A Appendix Declaration of Conformity 10 Index 13...

Страница 4: ...of individual models are given in the hardware manual for each xDAP product xDAP products are not intended for any application for which its performance is critical to human life and safety XDAP produ...

Страница 5: ...cations The i suffix is also carried forward to indicate the physical size of completely configured products The products covered by this document include the following xDAP7410 xDAP7410i xDAP7420 xDA...

Страница 6: ...ical specifications Equipment conforms to the physical dimensions and mounting specifications defined in standard IEEE 1011 10 and compatible with IEC 60297 19 inch rack standards Certain xDAP models...

Страница 7: ...grees Centigrade In general temperatures that are safe for humans are also safe for operating the xDAP units but sustained operation at relatively high ambient temperatures could accelerate degradatio...

Страница 8: ...to damage from connecting xDAP systems to signal sources that are referenced to a floating ground The analog inputs on xDAP products cope well with small shifts in common mode voltage levels since th...

Страница 9: ...e correctly seated and the panels tightly reattached before operating the equipment again Except for the modules that fit the covered slots and the external cables and connectors that attached to exte...

Страница 10: ...ated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interfer...

Страница 11: ...rocessors Model Numbers Base Chassis xDAP008 and xDAP008i Products base system configured with option cards xDAP7410 xDAP7410i xDAP7420 xDAP7420i xDAP7620 xDAP7620i CONFORM TO THE FOLLOWING EUROPEAN D...

Страница 12: ...5 standards 6 Front connector panels 9 Grounding 8 Hardware features 5 Installation guide 4 Intended Application 4 Operating Instructions 4 Operating power 6 Power connector 6 products 5 Repair 9 RoHS...

Отзывы: