C-26
Intel SATA RAID
▍
MS-7581
Intel SATA RAID
▍
MS-7581
d
egraded
raid a
rray
A RAID 1, RAID 5 or RAID 10 volume s reported as degraded when one of ts hard drve
members fals or s temporarly dsconnected, and data mrrorng s lost. As a result, the
system can only utlze the remanng functonal hard drve member. To re-establsh
data mrrorng and restore data redundancy, refer to the procedure below that corre-
sponds to the current stuaton.
Mssng Hard Drve Member
Make sure the system s powered off.
Reconnect the hard drve.
Reboot the system to Wndows; the rebuld wll occur automatcally.
Faled Hard Drve Member
Make sure the system s powered off.
Replace the faled hard drve wth a new one that s of equal or greater capacty.
Reboot the system to Intel RAID Opton ROM by press <Ctrl> and <I> keys smul-
taneously durng the Power-On Self Test (POST).
1.
2.
3.
1.
2.
3.
Select the port of the destnaton dsk for rebuldng, and then press ENTER.
4.
Содержание P55 GD80 - Motherboard - ATX
Страница 1: ... P55 GD80 series MS 7581 v1 x Mainboard G52 75811X1 ...
Страница 10: ......
Страница 14: ...1 4 Getting Started Getting Started P55 GD80 Series MS 7581 v1 X ATX Mainboard Mainboard Layout ...
Страница 16: ......
Страница 137: ...MS 7581 C 25 MS 7581 Select an update policy 8 Select Finish to begin recovery volume creation 9 ...
Страница 140: ......
Страница 150: ......