5. Insert speaker into mounting
hole with paint mask in place.
Tighten both screws on the baffle
face to actuate the mounting
wings. Firmly secure both screws.
DO NOT OVERTIGHTEN.
6. Remove paint mask unless
painting is required. In that case,
follow steps 7-10 when painting is
complete.
7. Adjust tap switch to proper
setting. Switch is preset to 8 Ohm
mode.
8. Attach grille safety clip by
placing the large end of the clip
over snap-fit post (1), then sliding
clip until small end snaps into
place around post (2).
1.
2.
1.
2.
[GETTING STARTED AND PRECAUTIONARY NOTES]
For proper connection and therefore full enjoyment of your new Phase Technology speakers, we encourage you to read this owners’ manual thoroughly,
even if you are very familiar with installing speakers.
Speaker placement is very subjective. Placement follows the guidelines for the developers of in-ceiling speakers, yet is also guided by personal preferences.
The proper spacing, location and adjustment of in-wall speakers are critical for complete enjoyment of your new speakers. This manual covers these topics
thoroughly.
When deciding upon a location, consider the following:
Make certain your speaker wires can be run to or are accessible from these locations. Make certain the wall or ceiling material is sturdy enough to
support the weight and vibration of the speakers. It is recommended that our pre-construction rough-in bracket assemblies be used whenever possible in
new construction (not included; AC-CI15-PCB). Make certain the area behind the speaker is free of obstacles such as wallstuds, electrical wiring, pipes,
etc. Each speaker should be positioned properly, relative to the listening areafor good coverage. Audio performance and room-to-room isolation will be
improved if there is some fiberglass insulation placed loosely behind the speaker.
3
1. Unpack speaker. Leave paint
mask in place until after speaker
is installed or painting is com-
plete.
3. Connect Euroblock to speaker
wires and connect to speakers.
2. Use hole template to mark
cutout on sheetrock. Use RotoZip
or other tool to cut hole. Hole size:
4” (102 mm) H x 4” (102mm) W.
[CI15 INSTALLATION IN A SHEETROCK CEILING]
4. If required, attach seismic
restraint system to hole in
clamping arm, then to reinforced
structure (saftey cable not
included)
9. Align tabs on snap-fit grille
with slots in baffle. Gently press
grille into place.