Inspection/Removing Product From Service
l
PFLs that have arrested a fall or are unable to pass an inspection shall be tagged “UNUSABLE” and disposed of in
accordance with local regulations.
l
Due to the nature of some fall arrest events, it is possible for the load indicator to not deploy. In the event that a PFL is
subjected to fall arrest forces and the load indicator does not deploy, the PFL still must be removed from service and
marked as “UNUSABLE” until it has been destroyed.
l
If the load indicator is deployed, immediately remove the PFL from service and mark it as “UNUSABLE” until it has
been destroyed.
Failure to follow these warnings can result in serious personal injury or death.
3
Product Specification
System Requirements
Component
ANSI/OSHA
CSA
EN/IRAM/NBR
Anchorage Connector Standard
ANSI Z359.1/OSHA 1926.502
CSA Z259.14/CSA Z259.15 EN 795 and/or TS 16415
Harness Standard
ANSI Z359.13/OSHA 1926.502 CSA Z259.15
EN 361
Connectors Standard
ANSI Z359.12/OSHA 1926.502 CSA Z259.12
EN 362
Retractable Type Fall Arresters
ANSI Z359.14/OSHA 1926.502 CSA Z259.2.2-17
EN 360 and EN 362
Structure Strength
3600 lbs (16 kN) certified
5000 lbs (22.2 kN) non-certified
5000 lbs (22.5 kN)
12 kN
PFL Materials
Component
Material
Case
Nylon
Drum
Aluminum
Pawl, Swivel Assembly,
Main Spring
Steel
Lifeline
1.00” (25.4mm) wide / 0.14” (3.6mm) thick HMPE / para-aramid blend OR 1.00” (25.4mm)
wide / 0.11” (2.8mm) thick Polyester
Connectors
Steel OR Aluminum
Energy Absorber
Nylon
Energy Absorber Pouch
Polyester
4
Harness Attachment
WARNING!
DO NOT rely on feel or sound to verify proper connector engagement. Ensure the connector is closed before use.
Failure to follow this warning can result in serious personal injury or death.
9
V-SHOCK® & V-SHOCK® EDGE
Personal Fall Limiter (PFL)
US
US
3 Product Specification