MSA Ultra Elite Responder Скачать руководство пользователя страница 15

ULTRA ELITE RESPONDER FACEPIECE

Installing the Lens Assembly and Lens Ring

Lens Assembly

P/N 10093933

Lower Lens Ring:

P/N 804805

Upper Lens Ring:

P/N 804804

1. Remove dirt, lens

fragments, or debris
from the groove.

2. Lubricate the groove

with Snoop (P/N
600920) or properly
mixed Confidence Plus
cleaner sanitizer
solution.

Keep the lens cover (P/N 10093932) on new lenses

until facepiece assembly is complete.

3. Align the lens centerline marks (top and bottom) with

the facepiece centerline marks.

Note:

Verify proper lens selection. NFPA approved lenses

bear the Identification Mark “A” at the top center of the
lens.

4. Insert the top of the

lens into the groove.

5. Work the groove

around the lens to seat
the lens.

Note:

The bottom lens-

centerline mark must line
up with the bottom
facepiece centerline mark.

6. Moisten the mating

surfaces of the
facepiece and lens
ring with Snoop
(P/N 600920).

7. Lubricate the lens

ring with Snoop
(P/N 600920).

15

TAL 012 (L) Rev. 1 - 10096395

Содержание Ultra Elite Responder

Страница 1: ...TAL 012 L Rev 1 MSA 2010 Prnt Spec 10000005389 I Mat 10096395 Doc 10096395 Ultra Elite Responder Facepiece MAINTENANCE AND REPAIR...

Страница 2: ...10093933 Lens Assembly 3 10025295 Lens Receptacle Inhalation Valve Disc 4 10082477 O Ring 5 10093919 Lens Port Plug 8 804805 Lower Lens Ring 6 804804 Upper Lens Ring 7 10093945 Screw 9 10083233 HUD B...

Страница 3: ...L Rev 1 10096395 ULTRA ELITE RESPONDER FACEPIECE 1 2 6 7 8 9 10 12 11 13 14 17a 18 19 20 21 22 23 24 25 27 28 29 30 31 32 33 34 7 16 15 32 35 37 36 3 5 38 39 26 4 17 15a Christo Lube Christo Lube Expl...

Страница 4: ...Cover for instructions 4 TAL 012 L Rev 1 10096395 Table of Contents Disassembly 4 SpeeD ON Head Harness 4 M7 HUD Mounting Bracket 4 Lens Ring and Lens Assembly 5 Nosecup 5 Component Housing Cover Rem...

Страница 5: ...bly P N 10093933 See Installing the Lens and Lens Ring for instructions 1 Use a Philips screwdriver to remove the screws from the lens rings 2 Remove the lens rings 3 Pull the lens out of the groove R...

Страница 6: ...the Exhalation Valve 1 Turn the facepiece so that the exhalation valve is down and allow the valve to fall into your hand Removing the Component Housing 1 Remove the component housing cover See Removi...

Страница 7: ...e piston f Use the o ring removal tool to remove the o ring g Discard the o ring Removing the Pneumatic Assembly 1 Remove the pneumatic tube a Use retaining ring pliers to remove the retaining ring b...

Страница 8: ...emoving the External and Internal Drinking Tubes 1 Pull the external drinking tube off of the connector 2 Pull the internal drinking tube out of the component housing 3 Pull drinking tube connector ou...

Страница 9: ...tabbed spoke with the centerline Note Alignment of the tabbed spoke with the centerline provides a visual guide when installing the drinking tube assembly and is not critical to facepiece function Not...

Страница 10: ...til it seats Installing the Speaking Diaphragm Speaking Diaphragm P N 804809 Retaining Ring P N 804808 1 With the gasket forward perforations facing the wearer place the diaphragm in the component hou...

Страница 11: ...o Lube P N 604070 to a new o ring d Install the o ring e Install the pneumatic nut Use the inch pound torque wrench socket and Pneumatic Nut Special Tool P N 10086032 and tighten to 8 in lbs Note Spec...

Страница 12: ...row end of the housing work the housing into the groove Note Ensure that the housing is captured completely by the groove and that the centerline marks are aligned 2 Insert the narrow end of the housi...

Страница 13: ...ket and screw provided See Installing the ClearCommand Communication System Mounting Bracket for instructions Installing the Exhalation Valve Exhalation Valve P N 814459 1 If necessary assemble the ex...

Страница 14: ...e c Stow the external drinking tube coupling Note To reduce snag hazards stow the tube under the flange Installing the Nosecup 1 Install the nosecup a Pass the drink tube through the x cut in he nosec...

Страница 15: ...piece assembly is complete 3 Align the lens centerline marks top and bottom with the facepiece centerline marks Note Verify proper lens selection NFPA approved lenses bear the Identification Mark A at...

Страница 16: ...cover before installing the M7 HUD Mounting Bracket See Removing the Component Housing for instructions If necessary remove the lens ring screws See Removing the Lens Ring and Lens Assembly for instru...

Страница 17: ...604070 2 Install the o ring Lens Receptacle Inhalation Valve Removing the Lens Receptacle Inhalation Valve 1 Stretch the inhalation valve disc off the post Note Lens assembly removed for illustration...

Страница 18: ...place the ClearCommand Communication System 1 Use a Phillips screwdriver to remove the lens ring screw 2 Use a Phillips screwdriver to remove the component housing ring screw 3 Remove the component ho...

Страница 19: ...the retaining ring P N 10023505 and firmly hand tighten 5 Install the nosecup a Stretch the nose cup over the exhalation valve flange b Stretch the nose cup over the retaining ring 6 Route the microp...

Страница 20: ...andards suggest user training in cleaning procedures Use MSA Confidence Plus Cleaning Solution P N 10009971 It cleans and disinfects in one operation retains germicidal effectiveness in hard water to...