UNPACKING AND INSPECTION

UNPACKING AND INSPECTION

The PAPR consists of the following components:
• motor-blower and battery pack as a single assembly 
• breathing tube
• polyurethane-coated support belt
• Saranex hood or the Advantage 3000 (Model 3100)

Thoroughly inspect all components of the respirator
before the device is used. Read and observe all NIOSH
approval limitations as they apply to using the PAPR.

1. Remove the hood, breathing tube and support belt

from the box. Check for signs of shipping damage.

2. Remove the motor-blower and battery pack, and the

two filters if included. Check for shipping damage.

Do not drop the PAPR. The case can be damaged by
impact. The blower can be loosened or the motor
shaft can be bent. If the unit is dropped, check the
case for cracks. Listen closely to the sound of the
motor. If the blower sticks or rattles, or if air output is
reduced, the entire motor-blower must be returned to
MSA or an authorized MSA Service Center for repair.

REMOVING AND INSTALLING COMBINATION
CARTRIDGES

1. Unthread and remove the cartridges, then separate

the pack from the motor-blower.

2. Look to see that the

gaskets located in each
cartridge receptacle on
the motor-blower are in
place.

Do not install the combination cartridges, or use the
respirator if the gaskets are missing or appear dam-
aged. If you do, the contaminant can be drawn into
the respirator and inhaled, resulting in serious respira-
tory injury or death.

3. Hold the PAPR in one hand.
4. Use your other hand to turn the cartridge/canister

clockwise and thread it down onto the sealing gasket.
Hand-tighten the cartridge.

5. Repeat steps 2 through 4 to install the other cartridge.

REPLACING THE CARTRIDGE

Use the cartridge immediately upon opening the bag.
Discard cartridge after each use. Do not exceed maximum
concentration and service life specified by governing pro-
tocol. The length of time the chemicals in the cartridge
will give protection depends on the concentration of the
contaminant(s) and the rate of breathing. When the mask
is adjusted properly, the wearer should not taste or smell
the contaminant, or experience eye, nose, or throat irrita-
tion. The wearer’s inhalation resistance should be as
experienced during training.

Return to fresh air immediately and attach a new cartridge if
you taste or smell the contaminant, experience eye, nose, or
throat irritation, or excessive inhalation resistance. Do not
use the cartridge after the expiration date on the label.

LITHIUM BATTERY PACKS

Lithium battery packs maintain over 85% of their original
charge for up to 10 years. Store the battery between 40˚
and 70˚ when not in use. This battery pack is a single-use
battery which will last for 4 hours under normal condi-
tions. When the pack reaches the end of its life, dispose
of it according to appropriate disposal procedures.

Do not recharge a Lithium battery. The Lithium battery
can explode. Failure to follow this precaution can
result in serious personal injury or death.

Note:

Unthread and remove the filters, then separate the

pack from the motor-blower.

1. Separating the battery pack from the motor-blower.

a. Be sure that the power switch is off. 
b. Hold the motor-

blower in one hand.

c. Use the index finger

of your other hand
to pull the metal
catch down toward
the MSA logo on the
front of the battery
pack. Pull the bat-
tery pack straight
up.

ASSEMBLING THE SUPPORT BELT TO THE MOTOR-
BLOWER

Slip the support belt through the belt loop on the motor-
blower.

7

TAL 209 (L) Rev. 1 - 10040590

WARNING

WARNING

CAUTION

CAUTION

Содержание OptimAir 6HC

Страница 1: ...emonstration of this equipment prior to use or for any additional information relative to use or repairs Call 1 800 MSA 2222 during regular working hours See separate insert for NIOSH approval information P N 10041484 This manual including the warnings and cautions inside must be read and followed carefully by all persons who have or will have the responsibility for using or servic ing the product...

Страница 2: ...User s Instructions and or maintenance manuals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators for use as surgical masks S Special or critical user s instructions and or specif ic use limitations apply Refer to User s Instructions before donning S SPECIAL OR CRITICAL USERS INSTRUCTIONS The respirator must not be worn in atmospheres which exceed any...

Страница 3: ...First determine the total concentration of the chemical mixture CMixture from the individual contaminant con centrations C1 C2 C3 using the following formula CMixture C1 C2 C3 The TLV of the mixture is found by using the following for mula where T1 T2 T3 are the individual contaminant TLVs and C1 C2 C3 are the individual contaminant concentrations Only use these equations if the contaminants prese...

Страница 4: ...e by trained qualified per sonnel only Failure to follow the above warnings can result in seri ous personal injury or death Do not use for urethane paints or other paints contain ing diisocyanates unless an appropriate cartridge change out schedule is developed Due to their poor warning properties over exposure can occur without user awareness and result in severe permanent dam age to the respirat...

Страница 5: ... sure limits and concentrations Selection then matches a specific media which traps known particulates and a spe cific sorbent which removes known gas or vapor contami nants resulting in purified air reaching the user The motor blower battery pack and filters are worn as an assembly on the support belt The breathing tube con nects the belt mounted assembly to the facepiece or hood The respirator m...

Страница 6: ...NOTES 6 TAL 209 L Rev 1 10040590 ...

Страница 7: ...tridge REPLACING THE CARTRIDGE Use the cartridge immediately upon opening the bag Discard cartridge after each use Do not exceed maximum concentration and service life specified by governing pro tocol The length of time the chemicals in the cartridge will give protection depends on the concentration of the contaminant s and the rate of breathing When the mask is adjusted properly the wearer should...

Страница 8: ...NOTES 8 TAL 209 L Rev 1 10040590 ...

Страница 9: ... strap insert one end of the strap in the slot located at the side of the suspension Then insert the remaining end of the strap in the slot on the other side 2 Insert the suspension into the hood 3 Turn the suspension so that the sweatband faces the hood lens 4 Attach the three Velcro strips on the suspen sion to the three strips inside the hood DONNING THE SARANEX HOOD PAPR Do not wear this respi...

Страница 10: ...ad 2 Push the back of the harness downward toward the neck until it is centered at the back of the head 3 If necessary hold the mask component housing with one hand and position the harness with other hand until obtaining a firm and comfortable fit against the face at all points 4 Tighten the two bottom straps so that the mask is snug against the face The top two harness straps should be flat agai...

Страница 11: ...TALLING COMBINATION CARTRIDGES 2 To install a fresh Lithium battery pack refer to Reattaching the Battery Pack OTHER GAS MASK USES NOT EVALUATED OR APPROVED BY NIOSH This PAPR when used with the combination cartridge is effective against the following chemical warfare CW agents GA GB Sarin GD VX Mustard and Lewisite and all biological agents Although not evaluated or approved by NIOSH for this app...

Страница 12: ...r death 3 Once the user and the protective equipment have been decontaminated proper disposal of affected equipment is to be performed Disposal is to be performed as required by federal state and or local laws that apply to CBA contaminated materials Failure to follow accepted safety and protection pro cedures when exposed to hazardous atmospheres can result in serious personal injury or death DEC...

Страница 13: ...BLIES 13 TAL 209 L Rev 1 10040590 P N 10041551 Saranex Hood Assembly Shoulder Length 492827 Polyurethane coated Support Belt 10041488 Battery Pack 487805 Filter Gasket 10041489 Motor Blower Assembly brush type motor ...

Страница 14: ...E VALVE ASSEMBLEY 2 84660 Exhalation Valve Body Assembly 3 82382 Exhalation Valve Cover 4 626254 Clamp 5 628082 O Ring 6 801035 Connector Insert 7 467175 Connector Nut 8 486472 Tube 9 482614 Suspension 481980 19 BREATHING TUBE ASSEMBLY 10 626254 Clamp 11 490689 Corrugated 12 626254 Clamp 13 801035 Connector Insert 14 628082 O Ring 15 467175 Connector 16 801074 Exhalation Connector ...

Страница 15: ...15 TAL 209 L Rev 1 10040590 20 ...

Страница 16: ......

Отзывы: