background image

 

Version 3.4       

 

20 

 

NC-217 

 

  Operating manual  

 

2.3.4

 

Recommendations on output ports rate 

2.3.4.1

 

Output interface capacity shall meet the following condition: sum of input 

data streams per time unit shall be less than channel capacity. 

Output data baud rate shall be higher than value of output channel capacity, which 

is calculated using the following formula 

n

n

n

f

C

)

(

E

(1) 

where 

n

 – a number of input channel; 

С

n

 – size of message on channel 

n

;  

f

n

 – transmission frequency on channel 

n

;  

E – required capacity of output channel in byte/s. 

Since there are various options for data coding in serial transmission, then under the 

following conditions required capacity bit per second shall comply with the parameters de-
scribed in table 4. 

Table 4 – Capacity value under various options of coding 

Stop bits 

Parity 

Capacity  

No 

Е * 9 

Even or Odd 

E * 10 

No 

E * 10 

Even or Odd 

E * 11 

Max. output channel capacity is 115200 bit or 14400 byte; it is recommended to use 

not more than 90% of channel capacity 102400 bit or 12800 byte. 

2.3.4.2

 

To calculate output channel capacity, it is necessary to sum data on three input 

channels and parameters represented in table 5. 

Table 5 – Parameters to calculate output channel capacity 

Channel № 

Size of message, byte 

Transmission frequency, Hz 

50 

10 

30 

100 

Therefore, output channel capacity shall make:  

E = (50 * 10) + (30 * 5) + (100 * 1) = 750 byte/s. 

For the output port set parity – “No”, number of stop bits – 1. Then output channel 

capacity shall be at least:  

E = 750 * 9 = 6750 byte/s. 

Hence, output port rate shall be set at least 7200 byte/s; output port rate is selected 

in available settings of the Product. 

Содержание NC-217

Страница 1: ...192174 Phone 7 812 622 23 10 info unicont com St Petersburg Russia Fax 7 812 362 76 36 www unicont com Limited Liability Company NPK MORSVYAZAVTOMATICA SUMMATOR COMBINER OF NMEA SIGNAL SENTENCES NC 2...

Страница 2: ...Marking and sealing 13 1 6 Packaging 13 2 INTENDED USE OF THE PRODUCT 14 2 1 Operational limitations 14 2 2 Usage preparations 14 2 3 Intended use 15 3 TECHNICAL SERVICE OF THE PRODUCT 21 3 1 General...

Страница 3: ...ment the safety regulations and rules applicable in the field shall be observed Only those who have read and understood this document and those who have had special training shall be permitted to oper...

Страница 4: ...nsumption W 20 Galvanic isolation from the mains Overvoltage protection Reverse polarity protection power supply connection Ports Interface input ports DATA_IN1 to DATA_IN4 4 RS 232 and RS 422 485 opt...

Страница 5: ...ports The data packet received on the outputs of DATA_I O 1 and DATA_I O2 ports is repeated to the ports OUT1 to OUT12 according to the customer s settings while there are data on DATA_I O 1 the Prod...

Страница 6: ...fier Purpose 1 LED indicator Power To display power status 2 Grounding stud M6x20 Main grounding element 3 Cable gland MG 20 To connect power supply 4 MG 16 To connect input data 5 To connect output d...

Страница 7: ...4 The Product s output ports allow for connection of NMEA 0183 receivers with RS 422 485 input interfaces and RS 232 ports OUT1 to OUT6 see figure 3 Power supply of NMEA signal receivers may be option...

Страница 8: ..._I O1 and DATA_I O2 ports NC 217 may be connected to PC through USB interface by a standard USB cable type A plug USB type A plug The Product s board is equipped with a USB connector type A to connect...

Страница 9: ...supply voltage failure on POWER IN terminal of the Product If a user needs to ensure alarm signaling of the Product s power failure along with the main standby ports switching AU 106 should be powere...

Страница 10: ...DATA_I O1 and DATA_I O2 are outfitted with Rt jumpers JP4 JP5 JP6 JP7 JP8 JP9 JP10 JP11 JP12 JP13 JP14 JP15 JP17 JP18 resistors terminators 120 Ohm used to match interface lines RS 422 and ter minals...

Страница 11: ...is outfitted with an individual LED of channel activity D3 D5 D6 D7 D11 D12 D13 D16 D17 D20 D21 D24 D25 D26 D30 D34 that lights up with green if data are avail able on the port Each DATA_I O1 and DATA...

Страница 12: ...12 NC 217 Operating manual Version 3 4 Figure 9 Layout of jumpers potentiometers and LEDs on the Product s PCB...

Страница 13: ...Product in case of paint coating damage Abrasive cloth 0 06 0 06 m To polish surfaces of the Product in case of paint coating damage 1 5 MARKING AND SEALING The Product has a nameplate indicating nam...

Страница 14: ...ctric installation and Safety rules for operation of electric installation while testing electrical circuits and insulation resistance 2 2 2 Visual check procedure Before switching the Product on a ob...

Страница 15: ...ct is receiving NMEA mes sages via any channel the line displays the corresponding number otherwise the Product displays In a similar way the bottom line displays status of output channels To activate...

Страница 16: ...Version 3 4 16 NC 217 Operating manual Figure 11 The structure of the Product s user menu...

Страница 17: ...s Parity CRC checking Messages for ports OUT1 to OUT 12 and press Enter Make further settings depending on the selected parameter Note To return to port select menu as well as exit the port select men...

Страница 18: ...s to cancel the made settings press key to return to the parameter select menu 2 3 3 5 Select CRC checking in the menu to provide the settings and LCD will display the following information see figure...

Страница 19: ...menu item changes it is formed by select of NMEA sentences headlines received on DATA_I O 1 or DATA_I O 2 ports as part of single frame duplicate data packet To select sentences use and Enter to send...

Страница 20: ...de scribed in table 4 Table 4 Capacity value under various options of coding Stop bits Parity Capacity 1 No 9 1 Even or Odd E 10 2 No E 10 2 Even or Odd E 11 Max output channel capacity is 115200 bit...

Страница 21: ...erform the technical service semi annual TS S shall be performed by maintenance personnel on the running equipment 3 2 SAFETY FEATURES While performing the TS observe the instructions in 4 2 3 3 MAINT...

Страница 22: ...es by clean cloth and dry them up 4 if varnish paint coating is damaged polish it with sand paper then clean with alcohol soaked cloth cover with varnish and dry up 1 person 5 minutes Check reliabilit...

Страница 23: ...safety and received proper qualifications Check grounding of the Product before providing any repair works Put a poster DO NOT switch on Under Operation on a power supply switch in OFF position Replac...

Страница 24: ...the interface cable Incorrect settings Provide correct settings The receiver is not receiving the data Interface cable is not connected Connect the interface cable Incorrect settings Provide correct...

Страница 25: ...required storage conditions 5 to 40 with the concentration of dust oil moisture and aggressive impurities in the air within the required limits for the working areas of production facilities After sto...

Страница 26: ...on in sealed and heated compartments sea transportation in dry service premises The Product must be transported in compliance with transportation rules applicable for each means of transport During lo...

Страница 27: ...ties You can also send an over age equipment unit to the manufacturer for its further disposal Proper disposal of Product components allows avoiding possible negative environmental and health impacts...

Страница 28: ...Version 3 4 28 NC 217 Operating manual APPENDIX INFORMATIVE OUTLINE AND INSTALLATION DIMENSIONS Figure A 1 The Product s outline and installation dimensions...

Отзывы: