MSA ICM Tx Unit NightFighter Скачать руководство пользователя страница 14

Low Battery Warnings

Replace the batteries in the appropriate device when
the low battery warning sounds. Use only recom-
mended battery types (see Description section of this
manual).  Change the battery in non-hazardous area
only. Failure to follow this warning can result in seri-
ous personal injury or death.

Note:

There are unique Low Battery Warnings for the

NightFighter Receiver and ICM Tx Unit or Nightfighter
transmitter which are each displayed by the NightFighter
Receiver.

1.  If there is a low battery in the receiver, one short

Yellow LED will flash.

2.  If there is a low battery in the ICM Tx Unit or

Nightfighter transmitter, double short Yellow LED
flashes will be displayed.

3.  If there are low batteries in the receiver and ICM Tx

Unit or transmitter, the Yellow LED will alternate single
and double flashes.

Replacing the Batteries in the ICM Tx Unit

Do not dispose of the battery in fire. It may explode.
Failure to follow this warning can result in serious per-
sonal injury or death.

1.  Loosen the four screws from the battery compartment

of the ICM Tx Unit then remove the battery cover (two
screws if Nightfighter Transmitter is in use).

2.  Insert the four AA batteries following diagrams inside

battery compartment (two AAA batteries if Nightfighter
Transmitter is in use). Insert each battery base firmly
into the case, then press down and in on the top of
the battery.

3.  Verify that the battery cover gasket is held in place

and is free from damage and debris and is not twisted
in the gasket retention groove in the battery cover.

4.  Before replacing the battery cover, be sure that the

rubber cover on the ICM Tx Unit is properly engaged
with the plastic housing.  The rubber cover has barbs
that hold it firmly against the plastic housing.  

5.  Replace the cover. Make certain that the battery

cover is oriented properly.  Align the angled tabs near
the battery cover screws with the battery cover.
Check that the rubber cover is no bunched or pinched
under the battery cover, otherwise the battery cover
may not remain water tight.  

6.  Evenly tighten cover screws by moving in an X pattern

(for ICM Tx Unit) around the cover. Be sure to tighten
the battery cover screws enough to provide adequate
compression on the battery cover gasket to prevent
dirt and moisture from entering the battery compart-

ment.  A torque of 6 in lbs is suggested.  Do not over-
tighten the screws. Do NOT use a thread sealant on
the screws.  

7.  Dispose of, or recycle batteries in accordance with all

applicable federal, state, and local regulations.

Replacing the Batteries in the NightFighter Receiver

Do not dispose of the battery in fire. It may explode.
Failure to follow this warning can result in serious per-
sonal injury or death.

1.  Loosen the screws to open battery door.
2.  Insert two AA batteries (Duracell MN1500 or Energizer

E91) according to the battery orientation noted inside
the compartment. (Older versions of the NightFighter
Receiver use AAA batteries).  The approved AAA bat-
tery is Duracell MN2400, Energizer E92, or Eveready
A92.

3.   Verify that the battery cover gasket is held in place

and is free from damage and is not twisted in the gas-
ket retention groove in the battery cover.

4.  Align  the battery cover to the RX housing and tighten

the screws evenly from side to side.  Be sure to tight-
en the battery cover screws enough to provide ade-
quate compression on the battery cover gasket to pre-
vent dirt and moisture from entering the battery com-
partment.  Do not overtighten the screws. Do NOT use
a thread sealant on the screws.  

5.  Dispose of, or recycle batteries in accordance with all

applicable federal, state, and local regulations.

Turning the ICM Tx Unit Off After Doffing the SCBA        

Turn off the ICM Tx Unit after doffing the SCBA; other-
wise batteries will be drained. The ICM Tx Unit does
not shut off automatically.

1.  Upon returning to fresh air, close the cylinder valve

completely and release all pressure from the system
following the SCBA instruction manual.

2.  When the pressure falls below 200 psig, turn the

device off by pressing the reset button 2 times in rapid
succession.

3.  The ICM Tx Unit will beep 1 time when the button is

pressed once. Pressing the button a second time will
then sound three beeps (“bee-bop-bop”) to indicate
that the unit is turned off. The lights will also stop
flashing.

WARNING

WARNING

DURING USE

14

TAL 507 (L) Rev. 1 - 10058881

WARNING

Содержание ICM Tx Unit NightFighter

Страница 1: ...which integrates with the SCBA These instructions in addition to the instructions supplied with the SCBA must be carefully read and followed by all persons who use or maintain this product This inclu...

Страница 2: ...with an Ultra Elite Facepiece 6 The NightFighter Heads Up Display consists of three 3 separate assemblies Bracket assembly attached to an Ultra Elite Facepiece Receiver mounted on the bracket assembly...

Страница 3: ...l Intrinsically Safe Rating The NightFighter Heads Up Display System and ICM Tx Unit is certified Intrinsically Safe in the United States for use in Class 1 Div 1 Groups A B C D and hazardous location...

Страница 4: ...4 TAL 507 L Rev 1 10058881 NOTES...

Страница 5: ...eiver on the facepiece which displays the air cylinder pressure in one quarter cylinder increments by an LED light pattern See chart 1 Assembly of Receiver to Facepiece Bracket With the facepiece layi...

Страница 6: ...6 TAL 507 L Rev 1 10058881 NOTES...

Страница 7: ...lso shuts the unit off after the cylinder valve is closed and all air pressure is bled from the unit o The center opaque lighted alarm button green red activates the full alarm mode with or without ai...

Страница 8: ...8 TAL 507 L Rev 1 10058881 NOTES...

Страница 9: ...pplied Manual Activation Sensor Mode with or without Pressure PreAlarm with or without Pressure Full Alarm with or without Pressure Deactivation of Full Alarm Deactivation of PreAlarm with Shake or mo...

Страница 10: ...4 ICM Tx Unit Specifications Functional Check of the ICM Tx Unit 1 Don the SCBA following the instructions in the SCBA User s Instruction Manual 2 When opening the cylinder valve to perform the SCBA s...

Страница 11: ...and the Audi Larm should sound Crack the bypass valve slowly to bleed off pressure until the ICM Tx Unit pressure read ing drops below the following values a 530psig approximately 2216psi system b 750...

Страница 12: ...NOTES 12 TAL 507 L Rev 1 10058881...

Страница 13: ...for the ICM Tx Unit in service Failure to follow this warning can result in serious personal injury or death Actual time remaining may be less than the calculated time displayed Increases in breathin...

Страница 14: ...in an X pattern for ICM Tx Unit around the cover Be sure to tighten the battery cover screws enough to provide adequate compression on the battery cover gasket to prevent dirt and moisture from enter...

Страница 15: ...signs of leaking covers or water retention in the case d Check rubber cover for damage e Check for damaged or missing buttons on the unit f Check for any visible signs of damage to compo nents g Check...

Страница 16: ...er on the ICM Tx Unit is properly engaged with the plastic housing The rubber cover has barbs that hold it firmly against the plastic housing 6 Replace the cover Make certain that the battery cover is...

Страница 17: ...assembly or fittings other than those supplied by MSA specifically for the Quick Fill System Use of any other transfilling hose assembly and or fitting may result in serious personal injury or death a...

Страница 18: ...o attach the Quick Fill System hose to the SCBA a Remove the rubber dust cap from the male inlet fit ting on the SCBA Be sure that the cylinder valve is fully opened b Remove the rubber dust cap from...

Страница 19: ...bber dust cover from the male Quick Fill System fitting d Push the female fittings on to the male fittings until they click in place Pull on the hose to be sure it snapped in place If serious leakage...

Страница 20: ...NOTES 20 TAL 507 L Rev 1 10058881...

Страница 21: ...e follow ing hose assemblies 485331 802687 802688 802689 802690 and 48332 for filling cylinders in IDLH atmospheres Do not Transfill be a Donor using a 3000psi URC Assembly The 3000psi URC Assembly ha...

Страница 22: ...female fitting or along the hose depressurize the hose and correct the prob lem Such leakage can result in increased fill time 2 To attach the Quick Fill System hose to the URC Assembly a Remove the r...

Страница 23: ...c Quickly replace the protective dust cap on the URC Assembly male regulator fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover preven...

Страница 24: ...eration and instructions manual PN 10023638 for additional war ranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Dep...