Note: 

Refer to chart 2 for the various audible and visual

indicators for the ICM Tx Unit.

Optional ID Tag (PN 10058545), for use with ICM Tx
Unit

Prior to pressurization of
the SCBA and during
inspection, the user can
“tag in” by depressing and
holding the top mode but-
ton (green) until the word
“data” appears in the dis-
play.  While “data” is dis-
played, hold the ID tag as
shown in the picture below.
The ICM will sound a single
beep confirming that the ID
data has been read.  If the word “data” disappears before
the ID tag has been read, the ICM Tx Unit has timed out
and the top mode button (green) must be depressed and
held again until “data” reappears.    

Correct ID Tag Orientation.  

The ID tag is not designed to be taken into a fire.  The
ID tag can also be used as accountability tag.   

Pressure Display

1.  Periodically check the pressure indicated on the ICM

Tx Unit display. It will display either remaining cylinder
pressure or calculated remaining service life.

2.  When the pressure reaches 25% of the rated service

pressure, the NightFighter Receiver will display one
flashing RED LED.

3.  When the NightFighter Receiver displays one flashing

RED LED, or when the pressure reaches approximate-
ly 25% of the rated service pressure, return to fresh
air.

Changing the ICM Tx Unit Display Mode

1.  Press the top mode button (green) once. This will

momentarily refresh the NightFighter Receiver display
as well as light the ICM Tx Unit display.

2.  While the ICM Tx Unit display is still lit, press the top

mode button (green) again. This will toggle the display
between remaining cylinder pressure and calculated
remaining service life.

The ICM Tx Unit has the ability to display calculated
remaining service life counting down to 0 psi or 25%
of the rated service pressure. The user must deter-
mine which option has been selected for the ICM Tx
Unit in service. Failure to follow this warning can
result in serious personal injury or death.

Actual time remaining may be less than the calculated
time displayed. Increases in breathing rate may reduce
remaining time more than expected. Use time indica-
tor as general guide only. The time displayed is based
on the continuation of the average breathing rate over
the last three minutes. Increases in the breathing rate
after checking the displayed time may result in less
remaining time than anticipated.

Failure to follow this warning can result in serious per-
sonal injury or death.

Starting Continuous Operations Mode

In Continuous Operations Mode, the life of the batter-
ies in the Nightfighter Receiver will be shortened. 

Failure to follow this warning can result in serious per-
sonal injury or death.

Note: 

The Continuous Pressure Mode can only be activat-

ed when the system is pressurized. Activate the
Continuous Pressure Mode as follows:

1.  Push the top mode button (green) on the ICM Tx Unit

and hold button in for 3 seconds (or push the
Operation Button on the Nightfighter transmitter).
Once LED’s lights come on, release button.

2.  Receiver will show air cylinder pressure level. LED

lights will stay on to show air cylinder pressure level
drop.

Turning Continuous Operations Mode OFF

Note:

The Continuous Operations Mode will deactivate if

low battery is present.

1.  With the ICM Tx Unit in Continuous Operation Mode,

push mode button (green) on the ICM Tx Unit and
hold the button in for 3 seconds (or push the
Operation Button on the Nightfighter transmitter).
Release button once LED lights go off.

2.  LEDs will revert to Automatic Mode showing only air

cylinder pressure status at each 25% increment of full
cylinder pressure.

Note:

The NightFighter Heads-Up Display System will

automatically turn itself OFF, approximately 60 seconds
after the apparatus is depressurized. (The single red LED
light will flash at this time).

WARNING

DURING USE

13

TAL 507 (L) Rev. 1 - 10058881

WARNING

WARNING

Содержание ICM Tx Unit NightFighter

Страница 1: ...which integrates with the SCBA These instructions in addition to the instructions supplied with the SCBA must be carefully read and followed by all persons who use or maintain this product This inclu...

Страница 2: ...with an Ultra Elite Facepiece 6 The NightFighter Heads Up Display consists of three 3 separate assemblies Bracket assembly attached to an Ultra Elite Facepiece Receiver mounted on the bracket assembly...

Страница 3: ...l Intrinsically Safe Rating The NightFighter Heads Up Display System and ICM Tx Unit is certified Intrinsically Safe in the United States for use in Class 1 Div 1 Groups A B C D and hazardous location...

Страница 4: ...4 TAL 507 L Rev 1 10058881 NOTES...

Страница 5: ...eiver on the facepiece which displays the air cylinder pressure in one quarter cylinder increments by an LED light pattern See chart 1 Assembly of Receiver to Facepiece Bracket With the facepiece layi...

Страница 6: ...6 TAL 507 L Rev 1 10058881 NOTES...

Страница 7: ...lso shuts the unit off after the cylinder valve is closed and all air pressure is bled from the unit o The center opaque lighted alarm button green red activates the full alarm mode with or without ai...

Страница 8: ...8 TAL 507 L Rev 1 10058881 NOTES...

Страница 9: ...pplied Manual Activation Sensor Mode with or without Pressure PreAlarm with or without Pressure Full Alarm with or without Pressure Deactivation of Full Alarm Deactivation of PreAlarm with Shake or mo...

Страница 10: ...4 ICM Tx Unit Specifications Functional Check of the ICM Tx Unit 1 Don the SCBA following the instructions in the SCBA User s Instruction Manual 2 When opening the cylinder valve to perform the SCBA s...

Страница 11: ...and the Audi Larm should sound Crack the bypass valve slowly to bleed off pressure until the ICM Tx Unit pressure read ing drops below the following values a 530psig approximately 2216psi system b 750...

Страница 12: ...NOTES 12 TAL 507 L Rev 1 10058881...

Страница 13: ...for the ICM Tx Unit in service Failure to follow this warning can result in serious personal injury or death Actual time remaining may be less than the calculated time displayed Increases in breathin...

Страница 14: ...in an X pattern for ICM Tx Unit around the cover Be sure to tighten the battery cover screws enough to provide adequate compression on the battery cover gasket to prevent dirt and moisture from enter...

Страница 15: ...signs of leaking covers or water retention in the case d Check rubber cover for damage e Check for damaged or missing buttons on the unit f Check for any visible signs of damage to compo nents g Check...

Страница 16: ...er on the ICM Tx Unit is properly engaged with the plastic housing The rubber cover has barbs that hold it firmly against the plastic housing 6 Replace the cover Make certain that the battery cover is...

Страница 17: ...assembly or fittings other than those supplied by MSA specifically for the Quick Fill System Use of any other transfilling hose assembly and or fitting may result in serious personal injury or death a...

Страница 18: ...o attach the Quick Fill System hose to the SCBA a Remove the rubber dust cap from the male inlet fit ting on the SCBA Be sure that the cylinder valve is fully opened b Remove the rubber dust cap from...

Страница 19: ...bber dust cover from the male Quick Fill System fitting d Push the female fittings on to the male fittings until they click in place Pull on the hose to be sure it snapped in place If serious leakage...

Страница 20: ...NOTES 20 TAL 507 L Rev 1 10058881...

Страница 21: ...e follow ing hose assemblies 485331 802687 802688 802689 802690 and 48332 for filling cylinders in IDLH atmospheres Do not Transfill be a Donor using a 3000psi URC Assembly The 3000psi URC Assembly ha...

Страница 22: ...female fitting or along the hose depressurize the hose and correct the prob lem Such leakage can result in increased fill time 2 To attach the Quick Fill System hose to the URC Assembly a Remove the r...

Страница 23: ...c Quickly replace the protective dust cap on the URC Assembly male regulator fitting This will form a redundant seal d Open the cylinder valve and return to fresh air immediately The dust cover preven...

Страница 24: ...eration and instructions manual PN 10023638 for additional war ranty information For a copy of the complete warranty or for information on submitting a warranty claim write to MSA Customer Service Dep...

Отзывы: