(7)
Optional:
Loosen grounding clamp.
a) Insert grounding cable and re-tighten grounding clamp with a torque of 2 Nm
(1.5 ft-lbf).
(8)
If needed, plug in and screw Ethernet plug with a torque of 0.4 Nm (0.3 ft-lbf).
(9)
Plug in power plug and screw union nut with a torque of 1.2 - 1.5 Nm (0.9 - 1 ft-
lbf) using a wrench SW14.
The device is assembled.
3.1.2 MSA HUB Fireservice for Truck Installation without Wall Brackets
(1)
Open housing by opening the right joints and unscrew the lid screws using a
Torx T20.
(2)
Optional: Insert SIM card.
Place the SIM card into the SIM card holder.
NOTE:
Do not touch the circuit board assembly. Observe electrostatic
procedures.
MSA HUB
10
GB
3 Assembly and Installation