NIOSH APPROVAL INFORMATION

Cautions and Limitations

A- Not for use in atmospheres containing less than 19.5 percent oxygen.
B- Not for use in atmospheres immediately dangerous to life or health.
C- Do not exceed maximum use concentrations established by regulatory standards.
D- Air-line  respirators  can  be  used  only  when  the  respirators  are  supplied  res-

pirable air meeting the requirements of CGA G-7.1 Grade D or higher quality.

E- Use only the pressure ranges and hose lengths specified in the user instructions.
G- If airflow is cut off, switch to filter and/or cartridge and immediately exit to clean air.
H- Follow established cartridge and canister change schedules or observe ESLI to

ensure that cartridges and canisters are replaced before breakthrough occurs.

I-

Contains electrical parts that may cause an ignition in flammable or explosive
atmospheres.

J- Failure to use and maintain this product properly could result in injury or death.
L- Follow the manufacturer’s User Instructions for changing cartridges and/or filters.
M- All approved respirators shall be selected, fitted, used, and maintained in accor-

dance with MSHA, OSHA, and other applicable regulations.

N- Never substitute, modify, add, or omit parts. Use only exact replacement parts

in the configuration as specified by the manufacturer.

O- Refer to User Instructions, and/or maintenance manuals for information on use

and maintenance of these respirators.

S- Special or critical user instructions and/or specific use limitations apply. Refer

to User Instructions before donning.

S - Special or Critical User Instructions

1. This  device  does  NOT  supply  oxygen.  Use  only  in  adequately  ventilated

areas containing at least 19.5 percent oxygen.

2. This respirator must be used in conjunction with the proper canister or fil-

ter for protection against specific contaminants.

3. Do not use when concentrations of contaminants are unknown or immedi-

ately dangerous to life or health (IDLH). (See the respirator NIOSH approval
matrix to determine if this device can be used for escape from those con-
centrations.)

4. Do  not  use  when  appropriate  exposure  limit  (OSHA,  PEL,  NIOSH  REL,

ACGIH TLV, etc.) is not known or when it is below the odor threshold or any
other established warning level for the contaminant.

WARNING

!

Содержание Duo-Flo

Страница 1: ...r repair call 1 800 MSA 2222 during regular work ing hours This manual including the warnings and cautions inside must be read and followed carefully by all persons who use or maintain this product in...

Страница 2: ...L Follow the manufacturer s User Instructions for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accor dance with MSHA OSHA and other ap...

Страница 3: ...r is a combination air supplied respirator and air purifying respirator It is approved by NIOSH for use with either a particulate filter or a chin style gas mask canister for respiratory protection ag...

Страница 4: ...er to practice switching the valve from one position to the other Respirator Use Limitations The wearer must comply with the following MSA respirator use limitations 1 Maximum Use Concentration Do not...

Страница 5: ...sed except for escape Time Use Limitation Canisters with an N95 filter shall be limited to 8 hours of use continuous or inter mittent against particulates Service time can be extended by performing an...

Страница 6: ...itative fit test is used a fit factor that is at least 1 000 for a full facepiece respirator and 100 for a half mask respirator shall be obtained before that respira tor is assigned to an individual Q...

Страница 7: ...ply section 4 Assemble apparatus as follows a Connect filter cartridge or canister to coupling nut on Duo Flo adapter check valve b Attach breathing tube between Duo Flo adapter tee and facepiece 5 Do...

Страница 8: ...y moving adjustment slides to length en or shorten straps Adjust the straps just snug enough so that no air leaks around the facepiece It is not necessary to pull the straps so tight that the the resp...

Страница 9: ...l No 7 665 1 Part No 455021 Hose Neoprene 25 ft Brass Model No 7 665 1 Part No 455022 Hose Neoprene 50 ft Brass Model No 7 665 1 Part No 471511 Hose PVC 15 ft Brass Model No 7 664 1 Part No 471512 Hos...

Страница 10: ...d then dry None of the metal plastic rubber leather cloth or glass parts will be adversely affected by the cleaning solution Cleaning and Disinfecting at or below 110 F will avoid possible overheating...

Страница 11: ...all instructions and warnings per taining to the respirator 2 The respirator and conditions meet the requirements outlined 3 The canister is the proper type for the contaminant or contaminants presen...

Страница 12: ...Rev 2 818369 Duo Flo Constant Flow Respirator Assemblies Chin Canister Type FACEPIECE SEE PAGES 17 18 56651 BREATHING TUBE ASS Y ALTERNATE 57156 BREATHING TUBE ASS Y DUO FLOW AIR LINE ADAPTER ASSEMBL...

Страница 13: ...5 480031 Snap Tite AL Locking TAL 7012 L Rev 2 818369 13 PLUG SEE PAGE 13 DUST COVER P N FITTING TYPE 486289 SCHRADER FOSTER STEEL 634450 SNAPTITE CEJN 634687 FOSTER BRASS HANSEN SST 634686 HANSEN BRA...

Страница 14: ...14 TAL 7012 L Rev 2 818369 Duo Flo Constant Flow Quick Disconnects for Flow Control Devices...

Страница 15: ...TAL 7012 L Rev 2 818369 15 FACEPIECE SEE PAGES 17 18 456651 BREATHING TUBE ASS Y 457158 BREATHING TUBE ASS Y ALTERNATE CHIN CARTRIDGE TYPE Duo Flo Constant Flow Respirator Assemblies...

Страница 16: ...ket Part No Part No Type 481934 481871 Snap Tite AL 481937 481873 Snap Tite Brass 481938 481874 Snap Tite SST 481935 481870 Foster Steel 481936 481872 Foster Brass 481940 481876 Hansen Brass 481939 48...

Страница 17: ...TAL 7012 L Rev 2 818369 17 Duo Flo Pressure Demand Quick Disconnects for Flow Control Devices...

Страница 18: ...471224 471225 480251 480252 480253 480254 MEDIUM MODEL 7 203 1 SPEAKING RUBBER DIAPHRAGM NOSECUP PART Black Black Green NUMBER Hycar Silicone Hycar With Less With Less 457126 471209 471212 471213 463...

Страница 19: ...IUM MODEL 7 753 1 SPEAKING RUBBER DIAPHRAGM NOSECUP PART Black Black Green NUMBER Hycar Silicone Hycar With Less With Less 484562 484563 484564 484565 484566 484567 484568 484569 484575 484576 484577...

Страница 20: ...20 TAL 7012 L Rev 2 818369...

Страница 21: ...TAL 7012 L Rev 2 818369 21...

Страница 22: ......

Страница 23: ......

Страница 24: ......

Отзывы: