QUICK-FILL SYSTEM OPERATION

the SCBA will separate. A hiss or pop may be heard
as the fittings separate and the high-pressure air is
sealed off.

5.  Immediately install the dust cover on the SCBA male

fitting.

6.  The SCBA cylinder is ready for service if the cylinder

pressure gauge is on the corresponding color band.

EMERGENCY OPERATIONS

1.  If you are transfilling in fresh air and the dust cover will

not stay on the SCBA male fitting because air is leak-
ing, correct the condition before using the SCBA.

2.  If you are transfilling in a contaminated atmosphere

and the dust cover will not stay on the SCBA male fit-
ting because air is leaking:

a. Immediately reconnect the Quick-Fill System hose

to seal off the leak and return to fresh air.

b. If you cannot reconnect the hose, reach behind and

close the cylinder valve. Air pressure in the regulator
will drop, and the leak will slow down.

c. Quickly replace the protective dust cap on the

SCBA male regulator fitting. This will form a redun-
dant seal.

d. Open the cylinder valve and return to fresh air

immediately. The dust cover prevents dirt, water,
and debris from entering the fitting, and acts as a
redundant seal.

TRANSFILLING BETWEEN SCBA FROM MSA
(EMERGENCY BREATHING SYSTEM)

Note:

The SCBA with the higher pressure reading is the

donor. The SCBA with the lower pressure is the receiver.
Transfilling between users of SCBA should be performed
only during life-threatening emergencies, or simulated
training exercises. Both donor and receiver must return to
fresh air immediately following the procedure.

Do not transfill if the donor's NightFighter Heads-Up
Display System is flashing. Failure to follow this warn-
ing may result in shorter escape time to return to fresh
air, causing serious personal injury or death.

NIGHTFIGHTER HEADS-UP DISPLAY SYSTEM 
RECEIVER PRESSURE READING

The NightFighter Heads-Up Display System Red LED
begins flashing to indicate that the pressure in the cylinder
has been reduced to 25% of its rated working pressure.
Remaining service time must be used for escape to fresh
air. If the donor's NightFighter Heads-Up Display System
Red LED begins flashing during transfilling, the donor
should disconnect and preserve his escape time.

1.  If the donor's NightFighter Heads-Up Display System

is not flashing and you have sufficient air to transfill air
to a receiver, (greater than1000psig for Low Pressure
SCBA and greater than 2000psig for High Pressure
SCBA), follow these steps.

a. Remove the 3 foot emergency transfill hose from its

protective pouch.

b. Remove the rubber dust cover from both female fit-

tings on the Quick-Fill System hose assembly.

c. Remove the rubber dust cover from the male quick-

fill fitting.

d. Push the female fittings on to the male fittings until

they click in place. Pull on the hose to be sure it
snapped in place.

If serious leakage is noticed from either of the two
female fittings, or anywhere along the hose, discon-
nect the female fittings and return to fresh air immedi-
ately. Failure to follow this warning may result in seri-
ous personal injury or death.

e. After approximately 30-60 seconds, pressure

between the SCBA cylinders will be equal.

f. Disconnect the Quick-Fill System hose from both

SCBA by pulling the gray sleeve back on both ends.
A hiss or pop may be heard as the fittings separate
and the high pressure air is sealed off.

g. Immediately install the dust cover on the quick-fill

male fitting. The dust cover prevents dirt, water, and
debris from entering the fitting, and acts as a redun-
dant seal.

EMERGENCY OPERATIONS

1.  If the dust cover will not stay on the SCBA or Quick-

Fill male fitting because air is leaking:

a. Immediately reconnect the Quick-Fill System hose

to seal off the leak and return to fresh air.

b. If you can not reconnect the hose, reach behind

and close the cylinder valve. Air pressure in the reg-
ulator will drop, and the leak will slow down.

c. Quickly replace the protective dust cap on the

SCBA male fitting. This will form a redundant seal.

d. Open the cylinder valve and return to fresh air

immediately.

2.  Preparing the Quick-Fill System for Storage:

a. Press in on the center of the quick-disconnect dust

cap to release any pressure in the Quick-Fill System
hose.

b. Roll up the hose and place it in its protective pouch.

Note:

Only persons trained in MSA Maintenance are

authorized to repair or disassemble the Quick-Fill System.
If repairs are required, contact your nearest MSA office.
Call 1-800-MSA-2222.  

18

TAL 601 (L) Rev. 5 - 10041214

WARNING

WARNING

Содержание BlackHawk MMR

Страница 1: ...tfighter Heads Up Display System complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept...

Страница 2: ...is attached or using this equipment in a manner or situation not intended by the manufacturers may result in damage to the NightFighter Heads Up Display System or equipment connected to the NightFigh...

Страница 3: ...f mobility For more information on self contained breathing appara tus use and performance standards please consult the following publications ANSI Standard Z88 5 Practices for Respiratory Protection...

Страница 4: ...d as long h the condition of the apparatus Failure to follow the above warnings can result in seri ous personal injury or death BEFORE USE Thoroughly inspect this air mask on receipt and before use Th...

Страница 5: ...regulator at approximately 80psig throughout the entire operating pressure range of the cylinder The regulator uses a large sintered filter which is easy to replace The filter captures particulates th...

Страница 6: ...cylinder to an empty cylinder by a LED light logic pattern The NightFighter Heads Up Display System s Transmitter is assembled to the gauge line hose The transmitter sends a signal to the receiver on...

Страница 7: ...rnings Note There are different low battery warnings If there is a low battery in the receiver single Yellow LED flash If there is a low battery in the transmitter double short Yellow LED flashes If t...

Страница 8: ...NOTES 8 TAL 601 L Rev 5 10041214...

Страница 9: ...fully closed clockwise 3 Reach behind and open the cylinder valve fully Note The NightFighter Heads Up Display System Receiver and Transmitter must be no more than15 inches apart otherwise the receiv...

Страница 10: ...lluminate in accordance with the NightFighter Heads Up Display System decreasing pressure sequence NightFighter Heads Up Display System Decreasing Pressure Sequence Four Green LEDs Steadily ON Three G...

Страница 11: ...y not seal properly with your face if you have a beard gross sideburns or similar physical characteristics see NFPA 1500 and ANSI Z88 2 An improper facial seal may allow contaminants to leak into the...

Страница 12: ...iately return to fresh air NightFighter Heads Up Immediately return to fresh Display System flashes air a return to Red LED INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulat...

Страница 13: ...tlined in this manual Ensure complete appara tus is clean and dry Ensure that facepiece head harness straps and harness adjustment straps are fully extended Place the complete apparatus in the storage...

Страница 14: ...re check that the strap and buckle are properly adjusted Open cylinder buckle Tighten cylinder strap by pulling on top outer strap It will be necessary to reposition the black plastic slide during ad...

Страница 15: ...400 7th Street SW Washington D C 20590 0001 Appropriately connect the cylinder to the filling system and refill Terminate the filling when the pressure reaches the service pressure and allow the cyli...

Страница 16: ...ing AAA Alkaline batteries use only Duracell MN2400 Energizer E92 or Eveready A92 Use of other batteries or a combination of batteries from different manufacturers will affect performance of unit and...

Страница 17: ...sure greater than 4500psig The high pressure air mask is rated for a maximum work ing pressure of 4500psig Failure to follow the above warnings may result in serious personal injury or death The user...

Страница 18: ...nsfilling the donor should disconnect and preserve his escape time 1 If the donor s NightFighter Heads Up Display System is not flashing and you have sufficient air to transfill air to a receiver grea...

Страница 19: ...e can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and oper...

Страница 20: ...NOTES 20 TAL 601 L Rev 5 10041214...

Страница 21: ...cepiece and components in clean warm 110 F water preferably running and drained e Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing with clean wate...

Страница 22: ...NOTES 22 TAL 601 L Rev 5 10041214...

Страница 23: ...essure Hose a Check the high pressure hose between the NightFighter Heads Up Display System Transmitter and first stage regulator Check for cuts or severe abrasions If present replace the hose the hos...

Страница 24: ...ns of heat or chemical related damages 10 Record Keeping Following inspection the date and initials of the desig nated person should be recorded on an inspection tag A more detailed record of the oper...

Страница 25: ...rn the regulator to a certified repairperson 3 NightFighter Heads Up Display System a MSA recommends that the function of the NightFighter Heads Up Display System warning device be checked by observin...

Страница 26: ...NOTES 26 TAL 601 L Rev 5 10041214...

Страница 27: ...sections and includes installation of the regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summarizes MSA s req...

Страница 28: ...r examination by MSA are proven to be defective Replacement equipment and or parts will be provided at no cost to the Purchaser F O B Purchaser s named place of destination Failure of MSA to successfu...

Отзывы: