DONNING

6.  Check for bypass oper-

ation. Grasp the red
knob and turn it
counter-clockwise.
Listen for air flow.
Close the bypass.

There must be a continuous flow of air when the
bypass knob is opened. If not, do not use the appara-
tus. The SCBA must be checked and corrected for
proper operation by an MSA trained or certified repair-
person before using it. Failure to follow this precaution
may result in serious personal injury or death.

LEAK AND NIGHTFIGHTER HEADS-UP DISPLAY SYS-
TEM CHECKS

Note: 

Continuous Operations Mode can only be activated

when SCBA is pressurized.

1.  Place NightFighter Heads-Up Display System into

Continuous Operations Mode. Press and hold
Operation Button on transmitter for 3 seconds. Once
LEDs come on, release button.

2.  Close the cylinder valve fully.
3.  Watch the NightFighter Heads-Up Display System

Receiver for 60 seconds. The LED light pattern must
not change.

If the NightFighter Heads-Up Display System
Receiver’s LED light pattern changes, do not use the
apparatus. The SCBA must be checked and corrected
for proper operation by an MSA trained or certified
repairperson before using. Failure to follow this pre-
caution may result in serious personal injury or death.

4.  Crack the bypass valve slowly to bleed off pressure.
5.  Watch the NightFighter Heads-Up Display System

Receiver while bleeding off pressure. The LEDs must
illuminate in accordance with the NightFighter Heads-
Up Display System decreasing pressure sequence. 

NightFighter Heads-Up Display System Decreasing
Pressure Sequence

Four Green LEDs, Steadily ON.

Three Green LEDs, Steadily ON.

Two Yellow LEDs, Flashing Continuously.

One Red LED, Flashing Continuously.

If the NightFighter Heads-Up Display System fails to
illuminate in the decreasing pressure sequence, do not
use the SCBA. The SCBA must be checked and cor-
rected for proper operation by an MSA trained or cer-
tified repairperson before using. Failure to follow this
precaution may result in serious personal injury or
death.

Note:

The NightFighter Heads-Up Display System will

automatically turn itself OFF, approximately 60 seconds
after the apparatus is depressurized. (The single Red LED
will flash at this time).

DONNING THE FACEPIECE

Do not wear eye glasses under the facepiece. The
temples or sidebars on eye glasses will prevent an air-
tight seal. If you must wear glasses, install the specta-
cle kit. Failure to follow this precaution may cause
inhalation of contaminated air, resulting in serious res-
piratory injury or death.

1.  Extend the facepiece straps fully. Place neckstrap

around your neck and don the facepiece by inserting
your chin first.

2.  Pull the head harness

completely over your
head.

3.  Tighten the lower (neck) harness straps first, by pulling

them straight back, not out.

4.  Tighten the temple

straps the same way.
Tuck in the ends of the
straps so that they lay
flat across the head.

10

TAL 601 (L) Rev. 5 - 10041214

WARNING

WARNING

WARNING

WARNING

Содержание BlackHawk MMR

Страница 1: ...tfighter Heads Up Display System complies with Part 15 of the FCC Rules Operation is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept...

Страница 2: ...is attached or using this equipment in a manner or situation not intended by the manufacturers may result in damage to the NightFighter Heads Up Display System or equipment connected to the NightFigh...

Страница 3: ...f mobility For more information on self contained breathing appara tus use and performance standards please consult the following publications ANSI Standard Z88 5 Practices for Respiratory Protection...

Страница 4: ...d as long h the condition of the apparatus Failure to follow the above warnings can result in seri ous personal injury or death BEFORE USE Thoroughly inspect this air mask on receipt and before use Th...

Страница 5: ...regulator at approximately 80psig throughout the entire operating pressure range of the cylinder The regulator uses a large sintered filter which is easy to replace The filter captures particulates th...

Страница 6: ...cylinder to an empty cylinder by a LED light logic pattern The NightFighter Heads Up Display System s Transmitter is assembled to the gauge line hose The transmitter sends a signal to the receiver on...

Страница 7: ...rnings Note There are different low battery warnings If there is a low battery in the receiver single Yellow LED flash If there is a low battery in the transmitter double short Yellow LED flashes If t...

Страница 8: ...NOTES 8 TAL 601 L Rev 5 10041214...

Страница 9: ...fully closed clockwise 3 Reach behind and open the cylinder valve fully Note The NightFighter Heads Up Display System Receiver and Transmitter must be no more than15 inches apart otherwise the receiv...

Страница 10: ...lluminate in accordance with the NightFighter Heads Up Display System decreasing pressure sequence NightFighter Heads Up Display System Decreasing Pressure Sequence Four Green LEDs Steadily ON Three G...

Страница 11: ...y not seal properly with your face if you have a beard gross sideburns or similar physical characteristics see NFPA 1500 and ANSI Z88 2 An improper facial seal may allow contaminants to leak into the...

Страница 12: ...iately return to fresh air NightFighter Heads Up Immediately return to fresh Display System flashes air a return to Red LED INSTALLING SLIDE MASK MOUNTED REGULATOR 1 Grasp regulator and orient regulat...

Страница 13: ...tlined in this manual Ensure complete appara tus is clean and dry Ensure that facepiece head harness straps and harness adjustment straps are fully extended Place the complete apparatus in the storage...

Страница 14: ...re check that the strap and buckle are properly adjusted Open cylinder buckle Tighten cylinder strap by pulling on top outer strap It will be necessary to reposition the black plastic slide during ad...

Страница 15: ...400 7th Street SW Washington D C 20590 0001 Appropriately connect the cylinder to the filling system and refill Terminate the filling when the pressure reaches the service pressure and allow the cyli...

Страница 16: ...ing AAA Alkaline batteries use only Duracell MN2400 Energizer E92 or Eveready A92 Use of other batteries or a combination of batteries from different manufacturers will affect performance of unit and...

Страница 17: ...sure greater than 4500psig The high pressure air mask is rated for a maximum work ing pressure of 4500psig Failure to follow the above warnings may result in serious personal injury or death The user...

Страница 18: ...nsfilling the donor should disconnect and preserve his escape time 1 If the donor s NightFighter Heads Up Display System is not flashing and you have sufficient air to transfill air to a receiver grea...

Страница 19: ...e can build up and freeze the buttons bypass valve and the release tabs Before entering or re entering a hazardous atmos phere make sure the buttons release tabs and bypass valve are ice free and oper...

Страница 20: ...NOTES 20 TAL 601 L Rev 5 10041214...

Страница 21: ...cepiece and components in clean warm 110 F water preferably running and drained e Clean the pressure demand exhalation valve by pressing in on the stem with a blunt object and flushing with clean wate...

Страница 22: ...NOTES 22 TAL 601 L Rev 5 10041214...

Страница 23: ...essure Hose a Check the high pressure hose between the NightFighter Heads Up Display System Transmitter and first stage regulator Check for cuts or severe abrasions If present replace the hose the hos...

Страница 24: ...ns of heat or chemical related damages 10 Record Keeping Following inspection the date and initials of the desig nated person should be recorded on an inspection tag A more detailed record of the oper...

Страница 25: ...rn the regulator to a certified repairperson 3 NightFighter Heads Up Display System a MSA recommends that the function of the NightFighter Heads Up Display System warning device be checked by observin...

Страница 26: ...NOTES 26 TAL 601 L Rev 5 10041214...

Страница 27: ...sections and includes installation of the regulator overhaul kits MSA breathing apparatus must be flow tested every year using an MSA approved flow test device The following table summarizes MSA s req...

Страница 28: ...r examination by MSA are proven to be defective Replacement equipment and or parts will be provided at no cost to the Purchaser F O B Purchaser s named place of destination Failure of MSA to successfu...

Отзывы: