OPERATION
AutoMaXX - series
11
3.4. Switching off the AutoMaXX (only positive pressure lung governed
demand valve)
To switch off, push operating button until stopper.
3.5. Removing the AutoMaXX
For AutoMaXX-AE and AutoMaXX-N:
(1) Switch off AutoMaXX-AE by pushing the red operating button.
(2) Unscrew handwheel and separate AutoMaXX from the mask.
(3) Uncouple medium pressure line:
Push the plug-in nipple into the coupling of the medium pressure line
forcefully and pull back the coupling sleeve at the same time.
For AutoMaXX-AS and AutoMaXX-AS-C:
(1) Press both operating buttons simultaneously and separate AutoMaXX from
the mask.
Alternative for AutoMaXX-AS-C: Unscrew handwheel.
(2) Remove medium pressure line:
Push the plug-in nipple into the coupling of the medium pressure line
forcefully and pull back the coupling sleeve at the same time.
3.6. Bypass system (only for AutoMaXX-AS)
A bypass system is available for the AutoMaXX-AS.
It is a safety system that supplies the user with continuously flowing air
independent of the lung governed demand valve. By turning the red handwheel,
the bypass is opened and can be set individually.
Warning!
When using the bypass, the compressed air consumption increases.
3.7. Additional function
Warning!
When using the flush button, the compressed air consumption
increases.
To flush out smoke and gases from the mask, push the flush button.