STORAGE
Store only undamaged respirators for further use. When
not in use, store the respirator in cool, dry, and clean
ambient air.
Do not distort the facepiece during storage. When dispos-
ing of the respirator or its components, do so in accor-
dance with local, state, and federal regulations.
Discard the canister/cartridge(s) if the original bag or car-
ton is opened or damaged. For gas mask application only,
see Storage and Shelf Life information below.
SHELF LIFE
Follow the shelf life expiration date stamped on the car-
ton, bag, and/or canister/cartridge(s) as applicable. The
expiration date will only apply if factory sealed and
undamaged or the proper procedure is followed, other-
wise the canister must be discarded.
Do not use an expired canister/cartridge(s). Failure to
follow this warning can result in serious personal
injury or death.
Storage and Shelf Life for Canister Part Numbers
10059903, 10067469, 10067491 and 10067470 Stored
Outside the Original Foil Packaging:
These canisters have a 5 year shelf life with the expiration
date printed on the foil bag. The canisters may be stored
outside the original factory packaging by using the follow-
ing procedure:
Approved Storage Configurations Outside the Original
Foil Packaging
Storage using the supplied cap/plug component
•
Remove the canister from the box and bag.
•
Locate the white block on the canister label.
•
Mark on the canister, in the white block, an expiration
date of 1 year (for formaldehyde canister an expiration
date of 6 months) from the date the canister was
removed from the packaging. This expiration date
must not to exceed the original expiration date printed
on the foil packaging.
•
The respirator must be
placed upright in the
plastic case).
•
10075204 Phosphine/Ammonia/ Chlorine/P100
•
10075205 Hydrogen Fluoride/P100
•
10075206 Formaldehyde/Acid Gas/
Chlorine Dioxide/Escape from Hydrogen
Sulfide/P100
•
10075207 Organic Vapor/P100
•
Ensure the lid is snapped tight and the case is closed.
•
Using the enclosed cap
and plug assembly as
shown in Figure A,
place the cap end over
the threaded outlet of
the canister as shown
in Figure B.
•
Insert the plug end on
the inlet of the canister
as shown in Figure C.
•
Using thumbs, press in the center of both the cap and
the plug ends to ensure the cap/plug is firmly in place
and the canister is sealed.
•
Discard cap/plug after each use.
Storage in user supplied case
•
Remove the canister from the box and bag.
•
Locate the white block on the canister label.
•
Mark on the canister, in the white block, an expiration
date of 1 year (for formaldehyde canister an expiration
date of 6 months) from the date the canister was
removed from the packaging. This expiration date
25
TAL 013 (L) Rev. 10 - 10028994
Содержание Advantage 3100
Страница 8: ...8 TAL 013 L Rev 10 10028994 NOTES...
Страница 10: ...10 TAL 013 L Rev 10 10028994 NOTES...
Страница 12: ...12 TAL 013 L Rev 10 10028994 NOTES...
Страница 20: ...20 TAL 013 L Rev 10 10028994 NOTES...
Страница 22: ...22 TAL 013 L Rev 10 10028994 NOTES...
Страница 24: ...24 TAL 013 L Rev 10 10028994 NOTES...
Страница 29: ...Refer to separate NIOSH Approval insert for approval information 29 TAL 013 L Rev 10 10028994...
Страница 30: ...30 TAL 013 L Rev 10 10028994 Refer to separate NIOSH Approval insert for approval information...
Страница 32: ......