background image

DONNING

DONNING THE RESPIRATOR WITH RUBBER HAR-
NESS

1. Loosen the two bottom

harness straps. Grip the
straps by inserting
thumbs through the
straps.

2. Insert chin well into the

lower part of facepiece,
then pull the harness
back over head.

3. Pull the back of harness

downward toward the
neck until centered at
the back of your head.

4. If necessary, hold the facepiece component housing

with one hand and position the harness with the other
hand, until obtaining a firm and comfortable fit against
the face at all points.

5. Tighten the two neck-

straps so that the mask
is snug against face.

Note:

Make sure the back

of the harness is centered
on the back of the head.

6. The top two harness straps must be flat against the

top of head.

Note:

Both top straps should be adjusted with button in

the same position so straps are equal in length.

7. If the mask does not feel snug up against face, loosen

the bottom straps and reposition the back of the har-
ness. Make sure that the back of the harness is posi-
tioned on the back of the head. If the mask does not
become snug against the face, remove the mask and
adjust the length of the top two straps.

Adjusting the Top Straps

1. Remove the strap from the button by pulling the loose

end of the strap away from the button.

2. Move the slide away

from the lens ring to
allow the strap to slide
through the lens ring
connection. Adjust the
length of the strap.
Secure the strap in
position by pulling the
strap onto the button.

3. Smooth the straps so

that they are flat. Move
the slide so that it is
located at the lens ring
connection.

13

TAL 013 (L) Rev. 10 - 10028994

Содержание Advantage 3100

Страница 1: ...Advantage 3000 Series Respirator P N 818082 CS CN This manual must be carefully read and followed by all persons who have or will have the responsibility for using or servicing Advantage 3000 APR Res...

Страница 2: ...iguration as speci fied by the manufacturer O Refer to User s Instructions and or maintenance man uals for information on use and maintenance of these respirators P NIOSH does not evaluate respirators...

Страница 3: ...l warnings and limitations specified 16 Wear impermeable protective clothing to prevent exposure to gases and vapors which can poison by skin absorption 17 Do not use this full facepiece with self con...

Страница 4: ...respirators before reuse in accor dance with the instructions provided This respirator filter is NOT for use by a children or b people with a medical condition that may be adversely affected by using...

Страница 5: ...left head harness attachment These facepieces do not pertain to the NIOSH approved CBRN application Contact MSA at 1 800 MSA 2222 for the correct facepiece Failure to follow this warning can result in...

Страница 6: ...l chloride diisocyanate Methylene chloride containin paints Nickel carbonyl Vinyl chloride Nitric Acid 6 TAL 013 L Rev 10 10028994 Canister for Chin Type Gas Masks Maximum Escape Part No MSA Canister...

Страница 7: ...P100 Canister must be replaced after each use against hydrogen flu oride not to exceed 12 hours to ensure the integrity of the P100 filter F MULTI USE LIMITATIONS OptiFilter XL only 1 Approved as a h...

Страница 8: ...8 TAL 013 L Rev 10 10028994 NOTES...

Страница 9: ...ned to ensure proper fit before using the respirator If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The respirator must also...

Страница 10: ...10 TAL 013 L Rev 10 10028994 NOTES...

Страница 11: ...n opening the bag For gas mask canister refer to the shelf life sec tion for storing the canister outside the packaging Discard canister cartridge s after each use Replace the canister cartridge s aft...

Страница 12: ...12 TAL 013 L Rev 10 10028994 NOTES...

Страница 13: ...e flat against the top of head Note Both top straps should be adjusted with button in the same position so straps are equal in length 7 If the mask does not feel snug up against face loosen the bottom...

Страница 14: ...he test as follows 1 Ensure respirator is assembled properly 2 Block off canis ter cartridge s inlet using the palm s of the hand s 3 Inhale gently and hold breath for 10 seconds If the seal is good t...

Страница 15: ...cover tab disengaging the com ponent housing tab 2 Slide the cover up to remove it from top tabs of the component housing 3 To install the cover insert the top tab of component housing into the top s...

Страница 16: ...ts on the back of the Lens bayonet connectors and gently stretch the valve openings to slip over the posts For Model 3100 a To replace the inhalation valves on the spider gas ket line up the holes in...

Страница 17: ...o screws which secure the lens rings 2 Separate the lens rings 3 Fold back the facepiece blank and remove the lens LENS REASSEMBLY Before installing a new lens check the blank groove for dirt or other...

Страница 18: ...button snaps into the button hole 3 Make sure the strap is not twisted and that the boss on end tabs side is facing up away from the inside of the facepiece 4 Thread the end tabs with the boss facing...

Страница 19: ...nd tabs side is facing up away from the inside of the mask 3 Don the mask and perform the Tightness Test Adapter Clips Reassembly Note All procedures are from face side of mask 1 The adapter clips are...

Страница 20: ...20 TAL 013 L Rev 10 10028994 NOTES...

Страница 21: ...must be per formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 To remove the facepiece insert your thumbs under each of the har...

Страница 22: ...22 TAL 013 L Rev 10 10028994 NOTES...

Страница 23: ...tions with the Confidence Plus Cleaning Solution b If the Confidence Plus Cleaning Solution is not used wash in a mild cleaning solution rinse thor oughly and submerge in a germicide solution for the...

Страница 24: ...24 TAL 013 L Rev 10 10028994 NOTES...

Страница 25: ...sing the supplied cap plug component Remove the canister from the box and bag Locate the white block on the canister label Mark on the canister in the white block an expiration date of 1 year for form...

Страница 26: ...er must be attached to the facepiece with the plug side of the cap and plug component secured into position DO NOT store the canister above 120 F Failure to fol low this warning can alter the performa...

Страница 27: ...through MSA Adjusting the Spectacles 1 To move the spectacles closer to your face pull the frame prongs out of the rubber block 2 To move the spectacles farther from your face push the frame prongs in...

Страница 28: ...spirator can be used in other configurations that stated in these User s Instructions Below is a list of these other configurations and the part number for the User s Instructions Review the NIOSH mat...

Страница 29: ...Refer to separate NIOSH Approval insert for approval information 29 TAL 013 L Rev 10 10028994...

Страница 30: ...30 TAL 013 L Rev 10 10028994 Refer to separate NIOSH Approval insert for approval information...

Страница 31: ...ve of MSA may bind MSA to any affirmation representation or modification of the warranty con cerning the goods sold under this contract MSA makes no warranty concerning components or acces sories not...

Страница 32: ......

Отзывы: