ASSEMBLING THE GAS MASK

Attaching the Canister

Place canister(s) onto inlet port carefully. Align the cutouts on the canister with
the lugs on the connectors. Hand-tighten by turning clockwise to stops to
ensure a good seal against the facepiece. When using a single canister, an inlet
cap plug must be used on the facepiece connector opposite the canister.
Hand-tighten clockwise as directed with the canister.

Note:

If using a thread adapter and threaded canister(s), the canister(s) must

seal against the gasket on the adapter. Hand-tighten the canister(s) clockwise
until tight. Refer to the facepiece component diagram to find the required can-
ister adapter parts.

USE OF INLET CAP PLUG

The design of the gas mask allows the use with a single canister on either the
right side or the left side of the facepiece. The receptacle on the side of the
facepiece opposite the mounted canister must be sealed off by an Inlet Cap
Plug. The Inlet Cap Plug must seal to the facepiece. Seal the cap onto the face-
piece by turning the cap clockwise onto the connector to stops.

DONNING THE RESPIRATOR

DONNING THE ADVANTAGE 1000 RESPIRATOR GASK MASK AND
ADVANTAGE 3200 WITH RUBBER HARNESS

1. Loosen the adjustable harness straps. Grip the straps by inserting thumbs

through the straps. Insert chin well into the lower part of facepiece, then
pull the harness back over head.

2. Pull the back of the harness downward toward the neck until it is centered

at the back of your head. If necessary, hold the component housing of the
mask with one hand and position the harness with the other hand, until
obtaining a firm and comfortable fit against the face at all points.

3. Tighten the adjustable straps so that the mask is snug against face. Make

sure the back of the harness is centered on the back of the head. The har-
ness straps must be flat against the head.

4. If the mask does not feel snug against face, loosen the adjustable straps

and reposition the back of the harness. Make sure that the back of the har-
ness is positioned on the back of the head. If the mask does not become
snug against the face, remove the mask and adjust the length of the straps.

DONNING THE ADVANTAGE 3200 GAS MASK RESPIRATOR WITH PLAS-
TIC ADVANTAGE 3000 HARNESS

Note:

There are two recommended donning procedures.

Donning Procedure A

1. Completely loosen the two bottom straps. Spread the straps of the head

harness with both hands and place chin into the mask. Pull harness over
head all the way, until plastic cradle lies flat on back of head.

2. Tighten neck straps evenly so that the mask is snug against the face.

TAL 8001 (L) Rev. 10 - 814175

7

Содержание advantage 1000

Страница 1: ...1 800 MSA 2222 during regular working hours TAL 8001 L Rev 10 MSA 2008 Prnt Spec 10000005389 F Mat 814175 Doc 814175 This manual including the warnings and cautions inside must be read and followed ca...

Страница 2: ...e or explosive atmospheres by MSHA NIOSH J Failure to properly use and maintain this product could result in injury or death L Follow the manufacturer s Users Instructions for changing cartridges and...

Страница 3: ...ined in the applicable NIOSH approval 3 For respirators with class P filters Replace filters when excessive breath ing resistance occurs while inhaling 4 For respirators with chemical canisters a User...

Страница 4: ...Chemical Agents or Biological Agents is pos sible but not expected or for escape from possible CBA contamination and controlled low level CBA atmospheres which do not exceed the maximum use concentra...

Страница 5: ...nce the user leaves the contaminated area he should enter the decontaminated area and follow the set decon procedure Failure to follow an acceptable decon procedure could lead to serious injury or dea...

Страница 6: ...S CANISTER S See separate insert for NIOSH Approval Information P N 818082 PREPARATIONS FOR USE The following inspection points must be checked before donning the gas mask A mask that fails the inspec...

Страница 7: ...arness straps Grip the straps by inserting thumbs through the straps Insert chin well into the lower part of facepiece then pull the harness back over head 2 Pull the back of the harness downward towa...

Страница 8: ...ll remain while the breath is held unless there is a leak in the seal If any leakage is detected around the facial seal readjust head harness straps and repeat the test until there is no leakage If ot...

Страница 9: ...hat users should be trained in cleaning procedure Alcohol should not be used as a germicide because it may deteriorate rub ber parts If not rinsed thoroughly cleaning agent residue may irritate the we...

Страница 10: ...use It is normal for this wax to come to the surface and can be cleaned by using MSA Confidence Plus P N 10009971 Rubber surface imperfections may be observed upon closer inspection of the mask and a...

Страница 11: ...TAL 8001 L Rev 10 814175 11...

Страница 12: ...12 TAL 8001 L Rev 10 814175...

Отзывы: