Summary of Contents for TH-134

Page 1: ...MESH NEBULIZER MODEL TH 134 MODEL TH 135 I n s t r u c t i o n s f o r u s e M E S H N E B U L I Z E R M O D E L T H 1 3 4 T H 1 3 5 READTHIS INSTRUCTION MANUAL CAREFULLY BEFORE USE...

Page 2: ...4 2 Intended purpose Page 4 3 Precautions Page 4 4 Notice for safety operation Page 6 5 Name of component Page 8 6 How to use Page 9 7 Clean and maintenance notice Page 10 8 Disinfection Page 11 9 Tro...

Page 3: ...nder the guidance of quali ed medical experts Environment This product is intended for use in a medical facility such as Hospital clinic and doctor s o ce in a room of general household and in open ai...

Page 4: ...e raised to 40 C the product shelf temperature will raise up to 50 C 15 Do not use nebulizer on top of or close to other electronic device 16 Do not drop the nebulizer Do not apply strong shocks to th...

Page 5: ...such as very weak spray volume etc before using please replace it When this appliance has not been used for a while if any part such as medical cup mouth piece or mask seems dirty please proceed with...

Page 6: ...ny irregularity or discomfort is observed please discon tinue use this appliance This product has built in a 20 minute shuto timer If it cannot be shuto automati cally discontinue using and consult yo...

Page 7: ...rn red and ash three times before turn o automatically However the no medication detector has the possibility not function if that mesh blocked by medication 3 Medical Cup Contain the medicine Suggest...

Page 8: ...ailure to do so could result in damage due to battery leakage 2 Discard the waste batteries according to local law 3 Open the medical cup cover and pour the medicine into the medical cup and close the...

Page 9: ...ur in some hot water and close the cover completely Press the power button and operate 1 2 minutes to discard all remaining medicine completely Ensure medicine be cleaned completely after each using o...

Page 10: ...indicator light is on the battery power is too low Please replace the battery immediately 2 Discard the waste batteries according to local law 3 Check the battery is installed correctly Open battery c...

Page 11: ...ncorrect functioning of the nebulizer and can generate unsafe situations In order to prevent such unsafe situations your nebulizer is designed and tested according to EN60601 1 2 standards These stand...

Page 12: ...battery indication 2 0V 2 2V orange light Low battery indication 2 0V red light Operation environment 10 40 C 30 80 RH Storage Transportationenvironment 20 70 C 85 RH Nebulization rate 0 2mL min 1 0mL...

Page 13: ...12 SYMBOL INFORMATION symbol referent Read instructions before use Manufacturer s Name Article number Serial number Class II Equipment Type BF equipment Disposal for separate collection CE mark Prote...

Page 14: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland ISO9001 ISO13485 Certi ed This device complies with European Council Directive 93 42 EEC on Medical Devices...

Page 15: ...B Well Swiss AG Bahnhofstrasse 24 CH 9443Widnau Switzerland IM_TH 134_TH 135_ISO_2616...