GB
MSA
MAINTENANCE
AND
SERVICE
Series 47K Gas Detector [SIL 2]
19
5.3.1 47K-HT-PRP
Relative response factors of tested gases with reference to Propane.
These values are only valid for new sensors and, unless otherwise stated, refer to
an ambient temperature of 110 °C. In this case the displayed values may vary by
up to ±20% from the target gas concentration.
Sample gas
100% LEL
in vol%
Propane relative
response factor
Response
time [secs]
t
50
*)
Response
time [secs]
t
90
*)]
Methane
4.4
0.52
< 8
< 14
*) Response times are with a flow through adapter and a gas flow of 1 l/min
5.3.2 47K-PRP
Relative response factors of tested gases with reference to Propane.
These values are only valid for new sensors and, unless otherwise stated, refer to
an ambient temperature of 20 °C. In this case the displayed values may vary by
up to ±20% from the target gas concentration. Response times stated in the
enclosed table may vary by ±20% depending on the tolerances of individual
sensors.
Sample gas
100%
LEL
in vol%
Propane relative
response factor
Response
time [secs]
t
50
*)
Response
time [secs]
t
90
*)]
Propane
1,7 1.00
1)
14 24
Acetaldehyde
4
0.64 ²)
Acetic acid
3)
4
1.51 ²)
Acetic anhydride
3)
2
1.56 ²)
Acetone
2,5 0.94
1)
9 24
Acetylene
2,3
0.76 ²)
Acrylonitrile
2,8
0.75 ²)
Allyl alcohol
2,5
0.90 ²)
Ammonia
15
0.38 ²)
Benzene
1,2
1.21 ²)
1.3-Butadiene
1,4
1.01 ²)
i-Butane
1,3
1.20 ²)
n-Butane
1,4
1.09 ²)
1-Butylene
1,6
0.94 ²)
n-Butanol
(Butylalcohol)
1,4
1.40 ²)
2-Butanone
1,8 1.13
1)
12 31
Содержание 47K Series
Страница 1: ...MSAsafety com Operation Manual Series 47K Gas Detector SIL 2 Order No 10052472 14 ...
Страница 36: ...GB DIMENSIONS MSA 36 Series 47K Gas Detector SIL 2 9 Dimensions 9 1 Gas Detector Ex e Junction Box ...
Страница 37: ...GB MSA DIMENSIONS Series 47K Gas Detector SIL 2 37 9 2 Gas Detector Ex d Junction Box ...
Страница 39: ...GB MSA DIMENSIONS Series 47K Gas Detector SIL 2 39 9 5 Junction Box ATEX 100 C Sensor 47K HT PRP ...
Страница 42: ...GB DIMENSIONS MSA 42 Series 47K Gas Detector SIL 2 9 7 Remote Calibration Adaptor ...
Страница 49: ...GB MSA APPENDIX Series 47K Gas Detector SIL 2 49 Notes ...
Страница 50: ...GB APPENDIX MSA 50 Series 47K Gas Detector SIL 2 Notes ...
Страница 51: ...GB MSA APPENDIX Series 47K Gas Detector SIL 2 51 Notes ...
Страница 52: ...Because every life has a purpose For local MSA contacts please visit us at MSAsafety com ...