GENERAL DESCRIPTION

The FireHawk M7 Responder APR is an air purifying respi-
rator intended for use in atmospheres which are not
immediately dangerous to life or health (non-IDLH). This
respirator is intended for applications which may require
the user to enter or exit a hazardous area, or work within
the area for a limited time.

Inhaled air is drawn through the canister which is designed
to remove, neutralize, and/or trap specific contaminates as
listed on the NIOSH approval insert. Exhaled air leaves the
facepiece through the facepiece exhalation valve. It is
important that the user becomes familiar with the applica-
tion and operation of the FireHawk M7 Responder APR
and ensures that it fits properly before use.

When properly fitted to the user, the Ultra Elite Responder
full facepiece with nosecup, head harness and Firehawk

®

Responder Regulator, combined with the appropriate can-
ister and breathing tube becomes a complete respiratory
protective device.

The respirator consists of the following subassemblies:

Ultra Elite

®

Responder (with nosecup)

Breathing Tube

Regulator

Canister

Neck Strap

Heads-Up-Display (HUD) (Optional)

Facepiece size is identified on the front of the facepiece
above the lens area.

RESPIRATOR USE LIMITATIONS

The wearer must comply with the following MSA respira-

tor use limitations:

A. MAXIMUM USE CONCENTRATION – Do not exceed

any of the following:

1. Routine Use –

a. 50 times the exposure limit for the contaminants

present if using a quantitative fit test method. Using
a qualitative fit test may reduce the maximum use
concentration. See the Respirator Fit Test section.

b. Immediately Dangerous to Life or Health (IDLH) con-

centration for any contaminant present.

B. The limitations outlined in the applicable NIOSH

approval

C. Any applicable limitation contained in a standard

established by regulatory agency (such as OSHA) with
jurisdiction over the wearer.

An appropriate cartridge change-out schedule must
be developed by a qualified professional, unless the
canister utilizes an end-of-service-life indicator. The
change-out schedule must take into account all fac-
tors that may influence respiratory protection includ-
ing specific work practices and other conditions
unique to the workers’ environment. If using against
substances having poor warning properties, there is
no secondary means of knowing when to replace the
cartridge/canister. In such cases, take appropriate
additional precautions to prevent overexposure, which
may include a more conservative change-out schedule
or using an air-supplied respirator or SCBA. Failure to
follow this warning can result in serious personal
injury or death. As a reference, a partial list of sub-
stances having poor warning properties follows:

7

TAL 803 (L) Rev. 0 - 10086002

Ultra Elite Responder

Ultra Elite Responder APR

Ultra Elite Responder APR

APR Respirator

Respirator Facepiece with

Respirator Facepiece without

Facepiece Model Number

ClearCommand Bracket

ClearCommand Bracket

7-2174-1

P/N 10082533 (small)

P/N 10082550 (small)

7-2174-1

P/N 10082532 (medium)

P/N 10082549 (medium)

7-2174-1

P/N 10082534 (large)

P/N 10082551 (large)

Facepieces are available in the following sizes and config-
urations.

Acrolein
Aniline
Arsine
Bromine
Carbon monoxide
Dimethyl sulfate
Hydrogen cyanide
Hydrogen selenide
Isocyanates
Methanol
Methyl bromide
Methyl chloride
Methylene chloride
Nickel carbonyl
Nitric Acid

Ozone
Phosgene
Phosphine
Phosphorous trichloride
Stibine
Sulfur chloride
Urethane or other diiso-

cyanate containing
paints

Vinyl chloride
Nitro compounds:
Nitrogen oxides
Nitroglycerin
Nitromethane

Содержание 10086004

Страница 1: ...rsons who rely on the FireHawk M7 Responder APR could sustain serious personal injury or death WARNING OPERATION AND INSTRUCTIONS The warranties made by MSA with respect to the product are voided if t...

Страница 2: ...ogical and nuclear dust particles Procedures for monitoring radiation expo sure and full radiation protection must be followed Z If during use and unexpected hazard is encoun tered such as a secondary...

Страница 3: ...ction with personal protective ensem bles that provide appropriate levels of protection against dermal hazard Failure to do so may result in personal injury even when the respirator is fitted properly...

Страница 4: ...NOTES 4 TAL 803 L Rev 0 10086002...

Страница 5: ...ear glasses install the spectacle kit 15 The user must perform a respirator fit test Quantitative Test or Qualitative Test and follow all warnings and limitations specified 16 Wear impermeable protect...

Страница 6: ...NOTES 6 TAL 803 L Rev 0 10086002...

Страница 7: ...esent B The limitations outlined in the applicable NIOSH approval C Any applicable limitation contained in a standard established by regulatory agency such as OSHA with jurisdiction over the wearer An...

Страница 8: ...Governmental Industrial Hygienists ACGIH Occupational Safety and Health Administration OSHA National Institute for Occupational Safety and Health NIOSH American Industrial Hygiene Association AIHA Co...

Страница 9: ...sure seal test before the user attempts to enter a toxic atmosphere The facepiece will not furnish protection unless all inhaled air is drawn through a suitable canister RESPIRATOR FIT TEST The user m...

Страница 10: ...NOTES 10 TAL 803 L Rev 0 10086002...

Страница 11: ...ring 4 Starting at the top stretch and push the rubber ring of the nose cup under the plastic retainer ring of the speaking diaphragm assembly 5 Continue stretching around nosecup ring and work it in...

Страница 12: ...sliding the strap through the slide It may be nec essary to use a ratcheting motion to completely tight en the strap Note canister connector is opposite the 90 degree elbow connection 4 For Configura...

Страница 13: ...esult in serious personal injury or death After verifying that the canister type is appropriate for use in the environment 1 Verify shelf life expiration date on carton bag and canister label has not...

Страница 14: ...e with C420 motor blower Refer to the NIOSH approval label for approved configurations In addition to this man ual the FireHawk M7 Responder PAPR manual P N 10086003 must be carefully read and followe...

Страница 15: ...har ness back over the head 3 Pull the back of the harness downward until it is centered at the back of the head 4 Tighten the two lower straps first by pulling them straight back not out Tighten the...

Страница 16: ...eal during use If adjusting the neck strap does not relieve the tension in the breathing tube a longer length breath ing tube can be used Failure to follow this warning may result in serious personal...

Страница 17: ...can result in seri ous personal injury or death Donning the FireHawk M7 Responder PAPR For Donning and negative pressure seal test Instructions refer to the FireHawk M7 Responder PAPR User s Instructi...

Страница 18: ...NOTES 18 TAL 803 L Rev 0 10086002...

Страница 19: ...formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 Remove strap from around the neck and support the canister 2 To remove the f...

Страница 20: ...NOTES 20 TAL 803 L Rev 0 10086002...

Страница 21: ...ghly wash the facepiece drink tube and nosecup and breathing tube in the cleaning solu tion A soft brush or sponge can be used to clean the soiled facepiece f Rinse the facepiece and components in cle...

Страница 22: ...NOTES 22 TAL 803 L Rev 0 10086002...

Страница 23: ...a Inspect the breathing tube for cracks tears and dirt b Inspect the canister connector assembly gasket for cracks tears dirt and distortion 4 Inspect the speaking diaphragm a Inspect speaking diaphra...

Страница 24: ...NOTES 24 TAL 803 L Rev 0 10086002...

Страница 25: ...N 805029 with the lens cover label P N 10082547 and lens plug P N 10082476 attached The bag is provided as a convenient storage container to protect the facepiece Replace the bag if it becomes dam age...

Страница 26: ...NOTES 26 TAL 803 L Rev 0 10086002...

Страница 27: ...approved in a CBRN application and must NOT be used Failure to follow this warning can result in serious personal injury or death Some canteens may not be leak tight Canteens used with the hydration...

Страница 28: ...ist along the edge of the elastic 6 Conduct a successful negative pressure seal test 7 Attach each of the arm straps to the front of the hood shroud using the Velcro attachment pads Adjust the arm str...

Страница 29: ...n place 5 To remove the spark cover gently squeeze the outside of the cover twist and pull the spark cover off 6 Check the spark cover before each use to ensure no sparks have created holes or warped...

Страница 30: ...NOTES 30 TAL 803 L Rev 0 10086002...

Страница 31: ...se User s Instructions Below is a list of these other configurations and the part number for the User s Instructions Review the NIOSH matrix to verify the con figuration that is being used is an appro...

Страница 32: ...representative of MSA may bind MSA to any affirmation representation or modification of the warranty concerning the goods sold under this con tract MSA makes no warranty concerning compo nents or acce...

Отзывы: