12
Fig. 14
Pull off protective cover
from canister.
5.2 Cleaning, Drying and Treating of Components
All components that have been in contact with the mouth or that have been
exposed to the exhalation air of the wearer must be cleaned and disinfected.
These are the following:
•
Breathing tube with mouthpiece, inhalation valve and nose clip
•
Connecting piece with check valve
•
Protective cover
•
Canister
•
Breathing bag with exhalation valve
All other components need only be cleaned if necessary. For the wet cleaning
it is recommended to use the Disinfectant AUER 90 according to instructions
for use. Drying of the components can be at room temperature or in an air
stream of max. 60°C.
After drying and prior to reassembly talcum powder is spread lightly on the
breathing bag (inside), the heat protector, the breathing tube (outside) and the
protective cover.
Attention: Shake off excess talcum powder!
No talcum powder inside the breathing tube!