Mode# C
D
Operating Mode
1
OFF OFF Normal Receiver (Factory Setting)
2
ON OFF Receiver with Time Delayed Output
3
OFF ON Dual Receiver
4
ON ON Receiver With Sequenced Outputs
5
N/A N/A Receiver With Ratchet Relay
Figure 2
1 2 3
5 6
4
7 8 9 10 11 12
0
N
The second
should be set like this.
Transmitter
then
1 2 3
5 6
4
7 8 9 10 11 12
0
N
If the
and one
code are set
the same, like this,
Receiver
Transmitter
Note #2 switch
in opposite position!
(Activates CP/RX)
Page 5
(82A022) CP/RXv0913
MODE #3—Dual Receiver
(Day/Night Function)
NOTE: This Mode requires BOTH the CP/RX and the RXM ADD ON MODULE
1. SELECT FREQUENCY: Remove CP/RX cover and select the desired frequency to match the transmitters via the
3-position slide switch on the receiver circuit board (Fig. 1).
2. SELECT SECURITY CODE: Select the desired security code to match the transmitters via the 12 dip switches on
the CP/RX circuit board (Fig. 1).
3. SELECT OPERATING MODE: Using table below select mode #3 via the dip switches marked C & D located on
the CP/RX printed circuit board.
4. Set one transmitter to match the security code of the CP/RX selected in step 2. Set a second transmitter to
this same code EXCEPT dip switch #2 which should be opposite to dip switch #2 on the CP/RX (Fig. 2).
5. Plug the 3-lead wire harness supplied with the RXM (purchased separately) into its connector on the RXM
circuit board and then plug the entire assembly onto the CP/RX circuit board (Fig. 3).
6. Mount the CP/RX in its intended location and plug the 5-lead wiring harness provided into its connector on the
CP/RX circuit board (Fig. 3).
7. Connect each device to be controlled to the appropriate wires (Fig. 3).
8. Connect power to the appropriate wires (Fig. 3).
ATTENTION:
Changing the operating mode or time delay settings after power is applied requires a 6
second delay for the new programming to take effect.
9. Install CP/RX cover with 4 screws provided.
ATTENTION:
If CP/RX is installed inside a door operator housing, drill a small hole in the housing and
pull the receiver antenna wire through it to ensure radio reception is not inhibited.
Figure 1
Table 1
Figure 3
HDRC™ Program 1-12
300 MHz Program 1-10
390 MHz Program 1-12
12 POSITION SECURITY
CODE SWITCH
antenna
RELAY 1
1 2 3 4 5 6 7 8 9 10 11 12
O
N
WIRE
HARNESS
PLUG
ADD ON MODULE
PLUGS
ClearPath
™
CP/RX
300MHz
390MHz
HDRC™
FREQUENCY SELECTION
SWITCH
(Activates RXM)
!
!
OPERATING
MODE
SELECTION
SWITCH
on
on
A B
TIME DELAY
SELECTION
SWITCH
on
on
C D
CP/RX
Multi-Mode Radio Receiver and Timing Module
INSTALLATION INSTRUCTIONS
HDRC
™
h
ClearPat
™
WHT
BROWN
VIO
N.C.
COM
N.O.
RED
BLK
+
-
12-40V AC
OR DC
1
3
5
6
7
antenna
300MHz
390MHz
HDRC™
FREQUENCY SELECTION
SWITCH
1 2 3 4 5 6 7 8 9 10 11 12
O
N
WIRE
HARNESS
PLUG
ADD ON MODULE
PLUGS
ClearPath
™
CP/RX
RXM
RELA
Y 2
RELAY 1
OPERATING
MODE
SELECTION
SWITCH
on
on
A B
TIME DELAY
SELECTION
SWITCH
on
on
C D
BROWN
VIO
WHITE
COM
N.O.
N.C.
3
2
1
Plug the wire harness into its connector BEFORE attaching the module
to the CP/RX circuit board.
8701 Castle Park Drive
Indianapolis, Indiana 46256
Telephone: (317) 842-2545
www.mssedco.com