background image

451-0308

MRV Communications, Inc. 

www.mrv.com

63

INDEX

Numerics

10/100 connectors

 56

4800 power management

 41

4800 series

connecting to

 41

5150 power management

 40

5150 series

connecting to

 40

5250 Power Management

 38

5250 Series

connecting to

 39

8-wire cabling

 61

A

adapter wiring

 59

adapters

 59

alarm input setup

 42

autobauding feature

 36

C

cables

ordering

 56

cabling

 20

signals

 61

command recall

 14

configured

 50

Configuring the LX-4000 Unit for the First Time

 25

connecting DC power

 21

connecting the power cable

 20

connecting to a serial port

 34

control output setup

 43

conventions

 13

crossover cables

 55

D

DB-25 connectors

 59

DB-25 pin assignments

 61

DC power

connecting

 21

diagnostic port connector

 55

DTE devices

connecting to LX-4000 Series

 61

DTE wiring

 59

E

environment

 19

environmental considerations

 19

error code definitions

 51

ethernet connection

 21

F

first time quick configuration

 25

flow control

 58

FLT - fault LED

 16

front panel LEDs

 16

G

Graphic User Interface (GUI)

accessing

 28

GUI EZ Configuration

 33

H

hardware installation

 15

help key

 14

I

iBoot factory default settings

 50

inlet connector lock

installing

 58

ordering

 58

installation

hardware

 15

installing Java Runtime Environment (JRE)

 29

Installing the LX Series

site requirements

 45, 48, 49

internet access

IP addresses

 36

internet environment

 36

IP address

assigning via the network

 27

manually setting

 28

IP information

obtaining

 27

J

Java

installing

 29

L

LED

fault

 16

link

 19

OK

 16

port status

 17

receive

 19

speed

 19

LINK LED

 19

login username

 23

default

 23

LX- 4000 Indicators

 16

Содержание LX-4000 Series

Страница 1: ...ernet MRV Americas Service and Support 295 Foster Street Littleton MA 01460 Tel 800 435 7997 Tel 001 978 952 4888 Outside U S Email service mrv com MRV America Sales 295 Foster Street Littleton MA 014...

Страница 2: ...93 6200 FCC Notice CAUTION This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Страница 3: ...sturbance may arise When such trouble occurs the user may be required to take corrective actions EXPORT NOTICE MRV models contain 128 bit encryption software Export of this product is restricted under...

Страница 4: ...4 MRV Communications Inc www mrv com 451 0308...

Страница 5: ...ort Optional 22 Powering On 22 System Login and Passwords 23 Resetting the Unit 23 Configuring the LX 4000 Series for the First Time 25 Configuring the LX 4000 Unit for the First Time 25 First Time Qu...

Страница 6: ...Control Output Setup and Usage 43 Appendix A Technical Specifications 45 Appendix B Factory Defaults 49 ppciboot Factory Default Settings 50 Appendix C POST Test Error Codes 51 Error Code Definitions...

Страница 7: ...wer 21 LX Series RESET Switch Location 23 Basic Menu Structure 36 Connecting the Temperature Humidity Sensor 38 Connecting the 5250 39 Connecting the 5150 40 Connecting the 4800 41 Typical Alarm Input...

Страница 8: ...8 MRV Communications Inc www mrv com 451 0308...

Страница 9: ...451 0308 MRV Communications Inc www mrv com 9 Tables LX 4000 Series Specifications 45 Temperature Humidity Sensor Specifications 48 LX 4000 Series Factory Defaults 49 POST Test Error Codes 51...

Страница 10: ...10 MRV Communications Inc www mrv com 451 0308...

Страница 11: ...nterface install Java Runtime Environment JRE and connect to the LX 4000 Series via telnet and SSH Chapter 4 Describes alternative port capabilities including temperature humidity sensors 4800 5150 po...

Страница 12: ...formation on network configuration initial setup how to set up for remote console functions RADIUS and system administration Provides basic information regarding the Network Management System NMS and...

Страница 13: ...entrally located or remote personnel to connect to the console or craft ports of any network element or server This serial connection allows administrators to manage and configure the remote network d...

Страница 14: ...er input messages prompts etc italics are used to indicate variables in command syntax descriptions Help Key At any prompt level you can press to display the available commands at that level The only...

Страница 15: ...n If you need to return the unit to MRV or your distributor you should return it in the original carton Package Contents The LX 4000 unit shipping carton contains the following items One rack mounting...

Страница 16: ...4 Figure 1 LX Series 4008 Front Panel Figure 2 LX Series 4016 Front Panel Figure 3 LX Series 4032 Front Panel Figure 4 LX Series 4048 Front Panel FLT Solid red indicates a fault condition exists or m...

Страница 17: ...or code After a POST test and a system software boot the lights indicate when a port is actively being used Rear Panel LEDs This section explains the rear panel LEDs and shows you a rear view of the v...

Страница 18: ...Mbps LED LINK 1 2 3 4 5 6 7 8 RCV LINK TELCO LINE 10 100 Interface Modem Port DIAG Port Port 0 9 10 11 12 13 14 15 16 10 100 ETHERNET DIAG 100 RCV 100 Mbps LED LINK 1 2 3 4 5 6 7 8 RCV LINK 24 48 60...

Страница 19: ...it Environmental and Installation Considerations Unit must be installed in an environment with 5 to 90 humidity noncondensing 0 40 C 32 104 F Do not choose a location where the unit will be exposed to...

Страница 20: ...upplied power cable to the rear of the LX 4000 unit and plug the other end into a 3 prong wall outlet Connecting the Ethernet Interface NOTE This port is set to auto negotiation by default You can man...

Страница 21: ...gnostic Port Port 0 in Appendix D for more information on DIAG port connections Connecting DC Power This section describes how to connect power to the DC version of the LX Series 4008 4016 and 4032 Th...

Страница 22: ...the LX 4032 modem port fields Powering On The Power On Self Test POST starts when you apply power to the LX 4000 Series unit The port status LEDs flicker and the FLT LED remains on while the test is...

Страница 23: ...nd escape are not supported Refer to the Password Enable section in the Subscriber chapter of the LX Series Commands Reference Guide for information on changing passwords Resetting the Unit To reset t...

Страница 24: ...Installing the LX 4000 Series 24 MRV Communications Inc www mrv com 451 0308...

Страница 25: ...File Refer to Applying Default Configurations to Other Units in the LX Series Configuration Guide Configuring the LX 4000 Manually via the CLI Refer to Upgrading Software with the ppciboot Main Menu...

Страница 26: ...set 6 Enter the appropriate information and press Enter to return to the Quick Configuration menu Once you enter a parameter value a data entry line specific to that parameter appears on the Quick Co...

Страница 27: ...ce Guide for information on specific commands To use Telnet refer to Connecting to the LX 4000 Series via Telnet or SSH on page 34 To use the web browser refer to Accessing and Configuring the Graphic...

Страница 28: ...ppears 10 Enter broadcast broadcast_address and press Enter The Intf 1 1 0 prompt reap pears 11 Enter exit and press Enter The Config 0 prompt appears 12 Enter gateway gateway_address and press Enter...

Страница 29: ...ownload the latest release of the Java plug in to your PC This download is performed automatically if the GUI sees that the plugin version is out of date or not available at all If for some reason you...

Страница 30: ...ning window may vary depending on your PC operating system 6 Click on Grant this session The Java Security Warning window closes The LX Series Console page reappears now with the console selection vis...

Страница 31: ...screen that appears depends on which mode you are authorized to configure and monitor Refer to Web Configure Mode on page 31 or Web Access Mode on page 32 depending on which mode you can access Web C...

Страница 32: ...f you have Web Access Mode your pre configured menu screen appears when you login Click on the various menu items on the left side of the window to perform preconfigured menu option tasks Menu Config...

Страница 33: ...ct Encrypted console or Non encrypted console and click Open Console 3 Enter a valid username and password and click Login The top level LX Console window appears 4 Login as superuser the default is s...

Страница 34: ...owing sections describe additional LX 4000 features you can access and configure Connecting to the LX 4000 Series via Telnet or SSH Telnet Directly into the Communication Server NOTE The default telne...

Страница 35: ...nd line interface port from a dumb terminal attached to an LX Series serial port which is set for access local or dynamic 1 Hit the return key several times to autobaud if autobaud is enabled the port...

Страница 36: ...it boots Autobauding Feature Autobaud is disabled on all ports The administrator can enable autobaud on a per port basis except for the DIAG port port 0 Default settings for the DIAG port port 0 are 9...

Страница 37: ...monitors when connected to an In Reach Temperature Humidity Sensor The Temperature Humidity Sensor provides an accurate measurement of the temperature humidity in the area in which your LX Series uni...

Страница 38: ...the commands used to configure and view your temperature humidity sensor through the CLI interface 5250 Power Management The 5250 Power Control Series family of products provides easy practical and se...

Страница 39: ...ess to power model ir5250 before performing any control and monitoring Use the following command in the Async Port Configure Mode to configure asynchronous port 1 as a 5250 port Async 1 1 0 access pow...

Страница 40: ...o RJ45 crossover cable and RJ45 to DB9F serial port adapter as required See the Technical Specifications in Getting Started with the MRV Communications 5150 Power Control Series for more information o...

Страница 41: ...ered devices The 4800 supports 48 VDC up to 70A The following section explains how to connect and install the 4800 Connecting the 4800 The 4800 Series is equipped with a single RJ45 RS 232 serial port...

Страница 42: ...use of these signals in greater detail Some common terms are Alarm Inputs LX Series port input signals DSR and CTS used in conjunction with the Signal Notice software feature to monitor real world ev...

Страница 43: ...wer to guarantee a low state and 2 4V or higher to guarantee a high state LX Series products do not support the use of TXD as the controlling voltage for Alarm Inputs DTR or RTS must be used DTR or RT...

Страница 44: ...low 2 5V 7 6mA absolute maximum drive A common Signal Ground is required The MRV Corporation IR 7104 family can provide true Form C SPDT Relay outputs rated to 30VDC 1A per contact if higher capacity...

Страница 45: ...nd CTS and Request to Send RTS Supports con current modem control Terminal Cabling Modular RJ 45 DTE Serial Line Speed LX 4000 Series 134 5 bps to 230 Kbps Number of Serial Ports LX 4008 8 ports LX 40...

Страница 46: ...communication co processors LX 4032 LX 4048 100 MHz PowerPC system board processor with integral 50 MHz communication co processor plus LX 4032 Eight 60 MHz RISC asynchronous communication co processo...

Страница 47: ...typ 0 105A 220V LX 4032DC 48VDC Nominal 20VDC to 72VDC Operating Range 0 6A 48VDC Dual Feed 99 BTU hr LX 4048AC 41W 140 BTU hr 0 24A 120V typ 0 13A 220V Minimum Software Requirements LX 4008 requires...

Страница 48: ...le 2 Temperature Humidity Sensor Specifications Item Description Interface Proprietary Maximum Cable Length 50 feet Operating Environ ment 5 to 90 humidity noncondensing Operating Temperature 0 to 40...

Страница 49: ...e DIAG port port 0 is the console manage ment port Auto Protocol Detect APD is disabled Autobaud is disabled 9600 8 1 None Quick Start is enabled Access is Local Flow Control is Xon Xoff All Ports Exc...

Страница 50: ...s configured at the factory to use a default set of initialization parameters that sets all ports to operate with asynchronous ASCII terminal devices Main Menu Configuration Factory Default Setting Bo...

Страница 51: ...Reading Invalid Pattern Value from CPLD Diagnostic Register 2020 Reading Invalid Pattern Value from Expansion CPLD Diagnostic Reg ister 2021 Reading Invalid Value from CPLD System Fail Status Register...

Страница 52: ...B0 CD1400 Reset delay timeout for Quadart 12 41C0 CD1400 Loopback operation timeout for Quadart 1 4210 CD1400 Loopback operation timeout for Quadart 2 4220 CD1400 Loopback operation timeout for Quadar...

Страница 53: ...he error code is displayed 3 You record that LEDs 3 and 4 turn on Figure 22 explains how to interpret the sample error code NOTE In hexadecimal 0 indicates the LED is OFF 1 indicates the LED is ON Eac...

Страница 54: ...nications Inc www mrv com 451 0308 A 1010 B 1011 C 1100 D 1101 E 1110 F 1111 Figure 22 POST Test Error Code Sample 1 All flash for 2 seconds 2 High error code 20 Hex 3 Cycle 1 through 8 4 Low error co...

Страница 55: ...ble for connecting to a DCE Data Communication Equipment device and the correct modular adapter male or female DB 25 connector which is essentially an RJ 45 to DB25 adapter Serial Device Connectors Th...

Страница 56: ...s MRV provides the following modular adapters for use with LX 4000 Series units Female DB 9 PN MX 350 0308 Female DB 25 PN MX 350 0181 Male DB 25 PN MX 350 0179 supports RING Male DB 25 PN MX 350 0180...

Страница 57: ...5 shows serial DB 25 pin assignments Figure 25 DB 25 Pins 9 Unused 10 Unused 11 Unused 12 Unused 13 Unused 14 Unused 15 Unused 16 Unused 17 Unused 18 Unused 19 Unused 20 Data Terminal Ready 21 Unused...

Страница 58: ...our terminal You can use this direct connect serial link to send commands to the boot loader and diagnostics This port is used to log system messages during bootup You can also use port 0 to manage an...

Страница 59: ...ng of pins 3 and 6 transmit and receive Flat eight wire cables are recommended Modular Adapters RJ 45 to DB 25 You can obtain adapters with male and female DB 25 connectors from MRV These adapters dir...

Страница 60: ...7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 5 20 2 7 3 8 6 4 CTS RING DTR XMT XMTGND RCVGND RCV DSR RTS Male RJ 45 Male RJ 45 Female RJ 45 Female RJ 45 Female DB 25 Crossover Cable MAXserver Connector Modula...

Страница 61: ...s cabling scheme provides XMT RCV DCD DSR DTR RTS CTS and two signal ground wires This cabling is provided through RJ 45 connectors Using this cabling scheme you can concurrently use modem control and...

Страница 62: ...Connector CTS DTR XMT GND RCV DCD RTS Male RJ 45 Connector Male RJ 45 Connector Straight Through Cable Adaptor Wiring MX 350 0180 Female RJ 45 to male DB 25 CTS RING DTR XMT XMTGND RCVGND RCV DCD RTS...

Страница 63: ...1 diagnostic port connector 55 DTE devices connecting to LX 4000 Series 61 DTE wiring 59 E environment 19 environmental considerations 19 error code definitions 51 ethernet connection 21 F first time...

Страница 64: ...rst time 25 LX 4008S front panel 16 LX 4016 front panel 16 LX 4032 front panel 16 LX 4048 front panel 16 M management station connecting to 21 manually setting the IP address 28 menu tree structure 36...

Страница 65: ...er 34 telnet port changing 34 temperature humidity sensor accuracy 48 cable length 48 connecting the 37 dimensions 48 environment 48 interface 48 weight 48 typographical conventions 14 U Unpacking and...

Отзывы: