2. General Troubleshooting
2.1 Error Display (Indoor Unit)
When the indoor unit encounters a recognized error
, the operation lamp will flash in a cor
responding series, the timer
lamp may tur
n on or begin flashing, and an er
ror code will be displayed. These error codes are described in the following
table:
Operation
Lamp
Timer
Lamp
LED
Display Error
Information
Solution
1 time
OFF
EH 00
Indoor unit EEPROM parameter error
TS18
2 times
OFF
EL 01
Indoor / outdoor unit communication error
TS19
3 times
OFF
EH 02
Zero-crossing signal detection error (for some models)
TS21
4 times
OFF
EH 03
The indoor fan speed is operating outside of the normal range
TS22
5 times
OFF
EC 51
Outdoor unit EEPROM parameter error (for some models)
TS18
5 times
OFF
EC 52
Condenser coil temperature sensor T3 is in open circuit or has short
circuited
TS25
5 times
OFF
EC 53
Outdoor room temperature sensor T4 is in open circuit or has short
circuited
TS25
5 times
OFF
EC 54
Compressor discharge temperature sensor TP is in open circuit or
has short circuited
TS25
5 times
OFF
EC 56
Evaporator coil outlet temperature sensor T2B is in open circuit or
has short circuited (for free-match indoor units)
TS25
6 times
OFF
EH 60
Indoor room temperature sensor T1 is in open circuit or has short
circuited
TS25
6 times
OFF
EH 61
Evaporator coil temperature sensor T2 is in open circuit or has short
circuited
TS25
12 times
OFF
EC 07
The outdoor fan speed is operating outside of the normal range
for some models)
TS22
9 times
OFF
EH 0b
Indoor PCB / Display board communication error
TS26
8 times
OFF
EL 0C
Refrigerant leak detected
TS27
7 times
FLASH
PC 00
IPM malfunction or IGBT over-strong current protection
TS29
2 times
FLASH
PC 01
Over voltage or over low voltage protection
TS30
3 times
FLASH
PC 02
High temperature protection of IPM module or High pressure
protection (for some models)
TS31
5 times
FLASH
PC 04
Inverter compressor drive error
TS33
1 time
FLASH
PC 08
Current overload protection (for some models)
TS28
7 times
FLASH
PC 03
Low pressure protection (for some models)
TS34
1 times
ON
--
Indoor units mode conflict (match with multi outdoor unit)
--
Содержание DIY E Star Series