Troubleshooting 22
7.4 EH 03 / EC 07 (Fan speed is operating outside of normal range diagnosis and solution)
Description
: When indoor / outdoor fan speed keeps too low or too high for a certain time, the LED displays the failure
code and the AC turns off.
Recommended parts to prepare:
• Connection wires
• Fan assembly
• Fan motor
• PCB
Troubleshooting and repair:
YES
Power off, then restart the unit after 2 minutes.
Is it within normal parameters?
Replace the fan motor
Does a problem remain?
The unit is operating normally
NO
Shut off the power supply, Rotate
the fan by hand.
YES
Does it turn easily?
Find the cause of the problem and resolve it
NO
Check the wiring of fan motor.
YES
Is it improperly wired?
Ensure proper connections
Measure the voltage for
the fan motor from the PCB.
YES
Replace the PCB
NO
Note: For certain models, outdoor PCB could not be removed separately. In this case, the outdoor electric
control box should be replaced as a whole.
Содержание DIY E Star Series
Страница 55: ...DIY E Star 4th Generation Series...