background image

4. MEASURING PROCEDURE

4-1 ACV measurement procedure

1)Rotate the function switch to the " ACV " position and

Power ON the meter.

2)Connect Red test lead to the " V 

 " input terminal and

Black test lead to " COM " input terminal.

3)Use the test lead measurement unknown AC voltage.
4)Read the Display. The show value will correspond to the

position selected. If the Display shows " ---- ", it
indicates an out-of-range measurement.

4-2 DCV measurement procedure

1)Rotate the function switch to the " DCV " position and

Power ON the meter.

2)Connect Red test lead to the " V 

 " input terminal and

Black test lead to " COM " input terminal .

3)Use the test lead measurement unknown DC voltage.
4)Read the display . The show value will correspond to the

position selected.  If the Display shows " ---- " it
indicates an out-of-range measurement.

Remark :

* Observe polarity when measuring DC voltage.

4-3 Resistance measurement procedure

1)Rotate the function switch to the 

 position and Power

ON the meter.

2)Connect red test lead to the " V 

 " input terminal and

black test lead to " COM " input terminal .
Connect test lead to the resistance.

7

Содержание DW-6160

Страница 1: ...sion measurement A l t h o u g h t h i s WATT Leakage METER is a complex and delicate instrument its durable structure will allow many years of use if proper operating t e c h n i q u e s a r e develo...

Страница 2: ...emove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories II 600V Pollution Degree 2 Altitude up to 2000 m...

Страница 3: ...AX MIN 6 3 4 Data hold button 6 3 5 Power function rotary switch 6 3 6 ACV DCV input terminal 6 3 7 Load terminal 6 3 8 Power source terminal 6 3 9 Battery Cover Compartment 6 3 10 Stand 6 3 11 RS 232...

Страница 4: ...001 A 0 01 A DCV 600 0 V x 0 01 V 0 1 V 20 k x 0 01 k 0 001 k 1 Low Watt measurement 999 9 Watt x 0 1 W True Power and Wide range 0 to 2500 Watt True RMS measurement of ACV ACA Leakage detect AC mA de...

Страница 5: ...m A current ACA 0 01 A to 10 00 A Over input mark indication Polarity Automatic switching indicates reverse polarity Zero Adjustment Automatic adjustment Sampling Time Approx 1 5 second Data Hold Free...

Страница 6: ...V adapter AP 9VA Accessories USB cable USB 01 RS232 cable UPCB 02 Data Acquisition software SW U801 WIN Hard carrying case CA 08 2 2 Electrical specifications 23 5 AC DC VOLTAGE Range Range 1 0 01V to...

Страница 7: ...ltage 120 AVC or Input current 1 ACA Beyond above input the resolution will still be 1 W Measuring Signals come from the top power plug input Accuracy is test under input signal is sine wave 50 60 Hz...

Страница 8: ...100 0 V ACA 0 001 A resolution is valid from 0 001 A to 1 200 A ACA 0 01 A resolution is valid from 1 2 A Measuring signals come from the top power plug input power source Auto range ACV ACA accuracy...

Страница 9: ...on 3 3 Record button MAX MIN 3 4 Data hold button 3 5 Power function rotary switch 3 6 ACV DCV input terminal 3 7 Load terminal 3 8 Power source terminal 3 9 Battery Cover Compartment 3 10 Stand 3 11...

Страница 10: ...1 Rotate the function switch to the DCV position and Power ON the meter 2 Connect Red test lead to the V input terminal and Black test lead to COM input terminal 3 Use the test lead measurement unknow...

Страница 11: ...nt power switch 6 It can read the Power Consumption value on the top LCD Display At the same time If your equipment exist current leakage It will show the leakage current value on the bottom LCD Displ...

Страница 12: ...232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 11 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232...

Страница 13: ...for Display ACV 50 DCV 34 K 39 38 W 47 m A 53 ACA 52 D13 When send the upper display data 1 When send the lower display data 2 D14 4 D15 Start Word RS232 FORMAT 9600 N 8 1 Baud rate 9600 Parity No par...

Страница 14: ...er by screwdriver then move the batteries 3 Replace with 1 5V x 8 PCs batteries and reinstate the cover 8 THE ADDRESS OF AFTER SERVICE CENTER 11 3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3...

Отзывы: