![MRC ASB-110-X Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/mrc/asb-110-x/asb-110-x_operation-manual_1845691030.webp)
- 30 -
05 Display time
for the value 1 – YES on top graph time is displayed, for the value 0 – NO,
time is not displayed.
05 Display date
For the value 1 – YES date is displayed on top graph, for the value 0 – NO,
date is not displayed.
Return to weighing
(see Draw. 9. - 5.1.2. – Return to weighing)
10. SETTING THE PARAMETERS
User can adjust the balance to existing conditions (filter) and own needs
(autozero, displaying last digit) by means of parameters in group <P4
Readout>.
Draw 22. Submenu Readout – internal setting
10.1. Setting filter
Dependly on conditions set the filter. If the conditions are conductive set
the filter as very fast (value of the parameter 01 Filter 1) and if the
conditions are bad (vibrations, draught) set the filter as slowly or very
slowly (value of the parameter 01 Filtr at 4 or 5). Efficience of filter is
different for range of weighing. The filter works slowler during getting to
weighed mass. It works faster when mass is the settled filer range
(parameter filter range accessed only from service menu – user does not
have acess).