Troubleshooting

TO AVOID ELECTRIC SHOCK, DISCONNECT POWER TO PUMP BEFORE SERVICING

METERING PUMP DOES NOT PRIME

1.

Check if voltage is available.

2.

Check liquid level in scent container. Replenish liquid, if necessary.

3.

Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.

4.

Check valves for contamination. Clean valves, if necessary.

5.

Check filter in container for contamination. Rinse filter under clean water.

Metering pump does not inject oil into steam room

1.

Check if voltage is available.

2.

Check liquid level in scent container. Replenish liquid, if necessary.

3.

Check for air bubbles in the suction hose or the pump head. To eliminate air bubbles see: Priming Pump.

4.

Check valves for contamination. Clean valves, if necessary.

5.

Check filter in container for contamination. Rinse filter under clean water.

6.

Check the pressure hose for kinking or jamming. Straighten or replace.

7.

Check if liquid is freely flowing through the atomizing nozzle when the metering pump is energized. Apply compressed air through the atomizing

nozzle. Attach the compressed air at the point of connection of the pressure hose.

8.

For eTempo/Plus: ensure the demand button light is on. the demand button light should be pressed during installation, the light willl turn on. In

the event of a power outage the button will need to be pressed again.

Metering pump oil delivery too much or too little

Contact Mr.Steam techincal service personnel at 1-800-76 STEAM (East Coast) or 1-800-72-STEAM (West Coast).

Technical Specifications

Dimensions:

7” L x 6.5” W x 4.5” H

___________________________________________
Weight:

5

pounds

___________________________________________
EN 60335
UL Listed
CSA Approved

___________________________________________
Motor voltage

120

VAC,

50/60

Hz

Power consumption, total [W]

12

Watt

List of Spare Parts

Description

Part No.

Pump Head

103861

Pressure/Suction Hose

EO1-1032

(ordered by the foot)

Eucalyptus oil, 1 liter

MS OIL 1

Lavender oil, 1 liter

MS OIL 2

Evergreen oil, 1 liter

MS OIL 3

Energizing Mint oil, 1 liter

MS OIL 4

Poho oil, 1 liter

MS OIL 5

Atomizing Nozzle

103918

Oil Injector

103983

Filter

103987

WARNING

!

AromaSteam IOM 08:AromaSteam 05.IOM  6/16/08  10:25 AM  Page 8

Содержание eTempo Plus

Страница 1: ...or fiberglass rooms Material Safety Data Sheet MSDS available upon request WARNING WARNING WARNING WARNING signals a situation where minor injury or product damage may occur if you do not follow instr...

Страница 2: ...ARNING WARNING signals a situation where minor injury or product dam age may occur if you do not follow instructions IMPORTANT NOTE THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY RELEVANT TO A PROBLEM...

Страница 3: ...tem is 1 5 ft If this minimum distance of 1 5 ft cannot be maintained install a radiation plate or heat insulation between the heat source and AromaSteam system Ambient temperature at and around the A...

Страница 4: ...iner and discard 3 Insert the suction hose with the open end from below through the hole in the container cap see Fig 3 4 Insert the filter into the scent container so that the filter rests on the bot...

Страница 5: ...am Head 90 T Atomizer Nozzle Pressure Hose Suction Hose Scent Container AromaSteam Demand Button Mounting Bracket AromaSteam System Steam Line Pump Line Cord 120V grounded receptacle required Tempo Te...

Страница 6: ...on the request cable NOTE When using generators hooked up in tandem the AromaSteam steam system should be connected to the contactor on the primary generator The atomizing nozzle should be connected...

Страница 7: ...e generator is steaming the pump will inject oil into the steam line at preset time intervals 3 If the generator is not steaming no oil will be pumped Note After the generator has been turned off the...

Страница 8: ...hose or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check filter in container for contamination Rinse filter under clean water...

Отзывы: