The AromaSteam system is qualified for use with Mr.Steam residential steam generators ONLY.
For use with residential steam rooms only. Not for commercial use.
1.
Locate the AromaSteam system to monitor the consumption of essential oils and for easy oil replacement.
2.
Mr.Steam strongly suggests that the warning sticker provided be placed in a conspicuous location near the
steam room.
3.
Mr.Steam AromaSteam System is designed and intended for indoor use only and is to be located indoors in a dry
clean location and not subject to moisture, condensation or similar high humidity environments.
4.
Do not install AromaSteam Systems outdoors.
5.
Do not install AromaSteam Systems in a location where water could freeze.
6.
Do not install AromaSteam Systems near flammable or corrosive materials and chemi-
cals. Installation in areas having high concentrations of chlorine (such as pool equip-
ment room) should be avoided.
7.
Attach the AromaSteam System onto a secure vertical surface.
8.
Provide access to AromaSteam System for servicing, and refills.
9.
The system should not be installed in areas accessible to children. A LOCKED ROOM
IS STRONGLY RECOMMENDED (ie: utility room)
10.
Height difference between AromaSteam System discharge and 90 degree
T
is to be
held to a maximum 6 ft. (see page 5).
Clearance to heat sources
•
Do not install the AromaSteam system directly below or above the Mr. Steam steam
generator where it is subject to heat.
•
Minimum distance between the AromaSteam system and a heat source (e.g. steam
generator, heating system) is
1.5
ft. If this minimum distance of
1.5
ft cannot be
maintained, install a radiation plate or heat insulation between the heat source and
AromaSteam system.
•
Ambient temperature at and around the AromaSteam system should not exceed 90˚ F.
Installing the 90 degree T and Atomizing Nozzle
1.
For optimal results locate a brass 90 degree
T
(not provided) and atomizing nozzle
in the steam supply line between 16" and 36" from the steam head (see page 5). If
using copper tubing for steam lines, install a female 1/2 NPT thread to sweat fitting
in the downward facing
T.
2. T
must face downward as shown (in figure 2).
3.
Screw the atomizing nozzle into 90°
T
fitting using teflon tape on the threads.
Note:
The further the 90°
T
is from the steam head (more than 36”) the more the fra-
grance degrades and be less effective. Conversely, the closer the 90°
T
is to the steam-
head (less than 16”) the less the fragrance will "blend" with the steam and the aroma
effect will be lessen.
IMPORTANT NOTE: Follow the installation instructions for the steam
pipeline in the Mr.Steam Residential Steam Bath Installation and Operating
Manual (PUR 101289). Visit www.mrsteam.com to download this document.
mr
.
steam
®
aromasteam
Operation and Installation Instructions
______________________________________________________________________________________________
General Installation
Steam Line
90˚ T
Figure 2
1/2 NPT
CAUTION
!
This room is equipped with an aromatic oil dispensing system.
Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.
mr
.
steam
®
43-20 34th Street , Long Island City NY 11101
1 800 76 STEAM www.mrsteam.com
PUR 100405
WARNING
!
3
AromaSteam IOM 08:AromaSteam 05.IOM 6/16/08 10:24 AM Page 3