mr. steam AromaFlo Скачать руководство пользователя страница 16

All diagrams for illustrative purposes only

Diagram 5

Diagram 4

Mounting the Caddy on a Wall:

1. Use a level to make sure the caddy is level.

2. Use the two mounting screws provided to secure the caddy  

to a wall stud (Diagram 2).

3. The fragrance and caddy are heavy. Failure to mount the caddy to a wall 

stud in a secure manner may result in spillage, excessively strong vapors 
or a fire hazard.

4. Install the lower screw first into a wall stud. Leave about 1/8” of the screw 

sticking out above the surface. Lower the caddy onto the screw so the 
caddy bottom keyhole rests securely on the screw.

5. Mounting screws have been provided. However, as construction materi-

als may vary, use other hardware (screws, anchors, etc. ) as required for 
secure mounting. Test the caddy for secure mounting.

6. Insert the fragrance container with the label facing outward so it is visible 

through the caddy window (Diagram 4). The label contains important infor-
mation.

7. Connect the fragrance container to the pump according to instructions on 

page 9 (Diagram 5).

8. Always keep the container in the caddy while it is connected to the dis-
pensing pump.

Mounting the Caddy on a Floor:

1. Use the two mounting screws provided to secure the caddy using the  

two holes at the bottom of the caddy (Diagram 3).

2. Mounting screws have been provided. However, as construction materi-

als may vary, use other hardware (screws, anchors, etc. ) as required for 
secure mounting. Test the caddy for secure mounting. 

3. Insert the fragrance container with the label facing outward in a manner 

it is visible through the caddy window (Diagram 4). The label contains 
important information.

4. Connect the fragrance container according to instructions on page 9 

(Diagram 5).

5. Always keep the container in the caddy while it is connected to the dis-

pensing pump.

 WARNING

!

Using a fragrance container that is not secured  

in the caddy, or using a caddy that is not mounted may 

result in spillage, excessively strong vapors or a fire hazard.

15

I N S T A L L E R   S E C T I O N

AromaFlo 

Operation and Installation Instructions 

®

All Drawings for Illustrative Purposes Only

Содержание AromaFlo

Страница 1: ...is material with the operator __________________________________ This installation operation and maintenance manual is for general reference The installation operation and maintenance manual supplied with the product must be used for installation operation and maintenance purposes Failure to use the installation operation and maintenance manual supplied may result in a property damage or personal ...

Страница 2: ... should be used in conjunc tion with consultations with an architect designer and contrac tor in determining factors necessary in providing a suitable and safe steam room MrSteam AromaFlo pumps are intended to be operated with MrSteam CU commercial steam bath gen erators and are to be installed strictly in accordance with the specific instructions contained in this manual and as supplied in the ma...

Страница 3: ...g difficulty breathing or eye nasal or throat irritation Sussman Automatic Corporation 43 20 34th Street Long Island City New York 11101 800 767 8326 PN PUR100381 3 02 WARNING Pressure Tube Assembly Suction Tube Assembly 2 I N S T A L L E R S E C T I O N AromaFlo Operation and Installation Instructions All Drawings for Illustrative Purposes Only REDUCETHERISKOFOVERHEATINGANDSCALDING 1 EXIT IMMEDIA...

Страница 4: ...ÕÌÊ vÊÌ iÊ i V Ê vÊ Ài Ê UÊ1ÃiÊ ÞÊ Ã À ÊÌ Ã Ê iÊ ÀiV ÕÌ ÀÞÊ measures against static discharge UÊ Ì ÃÊ i ÌÕÀi ÊiÌ Þ Ê V UÊ ÊV ÃiÊ vÊv Ài Ê1ÃiÊ Ó Ê ÀÞÊV i V Ê V Ê foam and water spray for extinction UÊ Ü ÞÃÊÃÌ ÀiÊÌ iÊ À Ìi ÊvÀ À ViÃÊ Ê ÊÃiVÕÀiÊ V Ì Ê ii ÊV Ì iÀÊÌ Ì ÞÊV Ãi Ê Ê store in a cool dry and well ventilated place UÊ ii Ê ÕÌÊ vÊÀi V Ê vÊV Ài UÊ iÊ À ÊÃÞÃÌi Ê ÃÊLii Êv VÌ ÀÞÊÃiÌÊÌ Ê deliver a s...

Страница 5: ...ragrance Container Cap with Hole for Tubing Fragrance Container Fragrance Caddy Pump Suction Tube Pump Line Cord Steam Solenoid with Outlet AromaFlo System Overview 4 I N S T A L L E R S E C T I O N AromaFlo Operation and Installation Instructions All Drawings for Illustrative Purposes Only ...

Страница 6: ...enoid valve Fragrance Caddy Steam Solenoid Valve Steam Head inside steam room Pressure Hose Pump General System Dimensions PUMP SPECS Dimensions 7 5 W x 4 5 H x 4 5 D Weight 5 pounds Motor voltage 120VAC 50 60 Hz Current Draw 0 5 Amps 5 I N S T A L L E R S E C T I O N AromaFlo Operation and Installation Instructions All Drawings for Illustrative Purposes Only ...

Страница 7: ...nsing system Leave room immediately if you have any adverse or allergic reaction including difficulty breathing or eye nasal or throat irritation Sussman Automatic Corporation 43 20 34th Street Long Island City New York 11101 800 767 8326 PN PUR100381 3 02 WARNING 6 I N S T A L L E R S E C T I O N AromaFlo Operation and Installation Instructions All Drawings for Illustrative Purposes Only REDUCETH...

Страница 8: ...tional tubing is needed please contact MrSteam Technical service at 1 800 767 8326 or 1 800 727 8326 Installation of Pressure Tube to the Pump 1 Insert the pressure tube through the hole of the pump tightening nut and collar and firmly push the tube onto the tube holder 2 Screw the pump tightening nut onto the pump and tighten the nut by HAND only Installation of Pressure Tube to the 90 T 1 Insert...

Страница 9: ...t valve cap and insert the suction tube through the cap Push the suction tube onto the foot valve Tighten the cap onto the foot valve 4 Unscrew the cap from the fragrance container and discard 5 Screw the cap onto the fragrance container 6 Make sure the Foot Valve rests on the bottom of the fragrance container IMPORTANT NOTE To prevent connection from leaking insert tubing holder completely into t...

Страница 10: ... injector tube from the pressure valve 7 Drain injector Repeat steps until the injector is filled 8 Save the fragrance injector as it may be needed when new fragrances are used 9 Close the priming valve completely by turning the knob clockwise Failing to close the valve will result in fragrance leaking from the priming port IMPORTANT NOTE If an extended pressure tube is special ordered then contac...

Страница 11: ...ock the AromaFlo pump must be suitably grounded according to National Electric and local Codes Disconnect all power supplies before proceeding Such wiring should be done by a licensed electrician NOTE Refer to the wiring diagram above for all wiring connections CAUTION CU Steam Generator Digital 1 Control CU AROMAFLO PROBE Steam Solenoid Valve Digitl One Control MrSteam Commercial Steam Solenoid C...

Страница 12: ...eam Technical Service Department before changing this setting Contact the MrSteam Technical Service Dept at 800 76 STEAM East coast or 800 72 STEAM West Coast for assistance or additional information Increasing the settings may introduce excessive concentration of fragrance into the steam room resulting in a health hazard Fragrance Setting Knob Power Button LED Light A R O M A F L O L2210 2 Rev C ...

Страница 13: ...container Replenish liquid if necessary 3 Check for air bubbles in the suction tube or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check foot valve in container for contamination Rinse foot valve under clean water Pump does not inject fragrance into steam room 1 Check if voltage is available 2 Check liquid level in fragrance ...

Страница 14: ...Tube Connector 3 pcs 104250 Tube per foot 104255 Foot Valve 2 pcs 104241 O Ring Kit 3 pcs 104275 Syringe 103983 Priming Tube 6 104322 Caddy 104319 REPLACEMENT PARTS 13 I N S T A L L E R S E C T I O N AromaFlo Operation and Installation Instructions All Drawings for Illustrative Purposes Only ...

Страница 15: ...s designed and intended for indoor use only Do not install outdoors 6 Do not install in an unheated location where water could freeze 7 Locate in an area where the ambient temperature does not exceed 88 F 8 Never locate the caddy near or on the steam boiler Doing so may result in fire property damage or personal injury 6 feet max Pump Caddy Fragrance Top Screw Hole Bottom Screw Keyhole Bottom Scre...

Страница 16: ...t the fragrance container to the pump according to instructions on page 9 Diagram 5 8 Always keep the container in the caddy while it is connected to the dis pensing pump Mounting the Caddy on a Floor 1 Use the two mounting screws provided to secure the caddy using the two holes at the bottom of the caddy Diagram 3 2 Mounting screws have been provided However as construction materi als may vary us...

Страница 17: ...allation WARNING CAUTION MrSteam Fragrance is Available in Two Fragrances FRAGRANCE PART NO CONTAINER VOL Eucalyptus CU EUCALYPTUS 1 Gallon A deeply refreshing aroma with cleansing effects eucalyptus may help open air passageways Lavender CU LAVENDER 1 Gallon A sweet lightly floral scent lavender may help soothe anxiety with its calming and restorative properties The Safety Data Sheet provides com...

Страница 18: ...ÕÌÊ vÊÌ iÊ i V Ê vÊ Ài Ê UÊ1ÃiÊ ÞÊ Ã À ÊÌ Ã Ê iÊ ÀiV ÕÌ ÀÞÊ measures against static discharge UÊ Ì ÃÊ i ÌÕÀi ÊiÌ Þ Ê V UÊ ÊV ÃiÊ vÊv Ài Ê1ÃiÊ Ó Ê ÀÞÊV i V Ê V Ê foam and water spray for extinction UÊ Ü ÞÃÊÃÌ ÀiÊÌ iÊ À Ìi ÊvÀ À ViÃÊ Ê ÊÃiVÕÀiÊ V Ì Ê ii ÊV Ì iÀÊÌ Ì ÞÊV Ãi Ê Ê store in a cool dry and well ventilated place UÊ ii Ê ÕÌÊ vÊÀi V Ê vÊV Ài UÊ iÊ À ÊÃÞÃÌi Ê ÃÊLii Êv VÌ ÀÞÊÃiÌÊÌ Ê deliver a s...

Страница 19: ...allations Only CAUTION CAUTION Recommended Setting OPERATION Powering Up the Pump IMPORTANT NOTE This step only needs to be performed during installation 1 The pump needs to be turned on before it can be used 2 Ensure power is being supplied to the pump 3 Press and hold the power button for 3 seconds The LED will turn solid green PUMP LED LIGHT KEY Flashing Green LED Pump is OFF Press and hold the...

Страница 20: ...EAM I 9410 S La Cienega Blvd Inglewood CA 90301 TEL 1 800 72 STEAM 2020 MrSteam and des A Lifetime of Pleasure AirTempo AromaFlo AudioWizard AutoFlush AutoSteam Butler Package ChromaSteam Clean Steam Every Time Club Therapy CT Day Spa Digital 1 Express Steam Feel Good Inc From Bathroom to Spa HomeWizard iButler iGenie iSpa Package iSteam iTempo iTempo Plus Linear Steamhead Making Wellness a Way of...

Отзывы: