Unvented Natural Gas Vent Free Room Heaters

CAUTION:

 Never connect heater to private (non-

utility) gas well. This gas is commonly known as well-
head gas. 

IMPORTANT:

 

Check your gas line pressure before 

connecting heater to gas line. Gas line pressure 
must be no greater than 14 inches of water. If gas 
line pressure is higher, heater regulator damage 
could occur.

CAUTION:

 Use only new black iron or steel pipe. 

Internally-tinned copper tubing may be used in certain 
areas. Check your local codes. Use pipe of larger 
enough diameter to allow proper gas volume to heater. 
If pipe is too small, undue loss of pressure will occur. 

Installation must include an equipment shutoff valve, 
union and plugged 1/8” NPT tap. Locate NPT tap within 
reach of test gauge hookup. NPT tap must be upstream 
from heater (see fi gure 12).

Figure 12

*A CSA/AGA certifi ed equipment shutoff valve with 1/8” 
NPT tap is an acceptable alternative to test gauge con-
nection. Purchase the CSA/AGA certifi ed equipment 
shutoff valve from your dealer. See Accessories, page 17.

IMPORTANT:

 Install an equipment shutoff valve in an 

accessible location. The equipment shutoff valve is for 
turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will 
prevent excess sealant from going into pipe. Excess 
sealant in pipe could result in clogged heater fuel train.

CAUTION:

 Use pipe joint sealant that is resistant to 

natural gas

Install sediment trap in supply line as shown in fi gure 
12. Locate sediment trap where it is within reach for 
cleaning. A sediment trap traps moisture and con-
taminants. This keeps them from going into heater. If 
sediment trap is not installed or is installed improperly, 
heater may not run correctly.

IMPORTANT:

 Hold pressure regulator with wrench 

when connecting it to gas piping and/or fi ttings.

Pressure 
Regulator

Heater 
Cabinet

Ground Joint Union

Equipment 
Shutoff Valve

From Gas Meter 
(4” W.C. to 10.5” 
W.C. Pressure)

Tee Joint

1/8” NPT Plug Tap

Cap

Pipe Nipple

Tee Joint

3/8” NPT Pipe Nipple

Sediment 
Trap

Test Gauge 
Connection

Reducer Bushing 
to 1/8” NPT

3” Minimum

CHECKING GAS CONNECTIONS

WARNING:

 Test all gas piping and connections for 

leaks after installing or servicing. Correct all leaks 
at once. 

WARNING:

 Never use an open fl ame to check for 

a gas leak. Apply a mixture of liquid soap and water 
to all joints. Bubbles forming show a leak. Correct 
all leaks at once. 

PRESSURE TESTING GAS SUPPLY PIPING 
SYSTEM

Test pressure in Excess of ½ psig (3.5kPa)

1.  The appliance and its appliance main gas valve 

must be disconnected from the gas supply 
piping system during any pressure testing of 
that system at test pressures in excess of 

½

 

psi (3.5 kPa). The appliance must be isolated 
from the gas supply piping system by closing 
its equipment shutoff valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than 

½ 

psi (3.5 

kPa).2.  Cap off open end of gas pipe where 
equipment shutoff valve was connected.

3.  Pressurize supply piping system by either using 

compressed air or opening main gas valve on 
or near gas meter.

4.  Check all connections and joints in gas supply 

piping system. Apply mixture of liquid soap and 
water to gas joints. Bubbles forming show a 
leak.

5.  Correct all leaks at once.

6.  Depressurize and relieve pressure in supply 

piping system.

7.  Reconnect heater and equipment shutoff valve 

to gas supply. 

8. Reconnected 

fi ttings must be checked for leaks 

in next section. 

Test Pressure Equal To or Less Than ½ psig (3.5 kPa)

1.  Close equipment shutoff valve (see fi gure 13).

2.  Pressurize supply piping system by either using 

compressed air or opening main gas valve on 
or near gas meter.

3.  Check all joints from the gas meter to equip-

ment shutoff valve (see fi gure 14). Apply 
mixture of liquid soap and water to gas joints. 
Bubbles forming show a leak.

4.  Correct all leaks at once.

5.  Depressurize and relieve pressure from supply 

piping system.

Содержание MHVFBF20 NGT

Страница 1: ...ectrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in w...

Страница 2: ...ide poisoning WARNING This appliance is equipped for natural gas Field conversion is not permitted WARNING Do not use any accessory not approved for use with this heater WARNING Any change to this heater or its controls can be dangerous Do not place clothing or other flammable ma terial on or near the appliance Due to high temperatures heater should be kept out of traffic and away from furniture a...

Страница 3: ...nters the heater 4 If heater shuts off do not relight until you provide fresh outside air If heater keeps shutting off it requires servicing 5 Turn off and unplug heater and let cool before servicing Only a qualified service person should service and repair heater 6 Do not run heater Where flammable liquids or vapors are used or stored During dusty conditions 7 Before using furniture polish wax ca...

Страница 4: ...rom National Fuel Gas Code NFPA 54 ANSI Z223 1 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the three following ventilation classifications 1 Unusually Tight Construction 2 Unconfined Space 3 Confined Space This heater must not be installed in a confined space or unusually tight construction unless provisions are pro vided for adequate combustion and ventilat...

Страница 5: ...hr Total 60 000 Btu hr 4 Compare the maximum Btu hr the space can support with the actual amount of Btu hr used Example 51 800 Btu hr maximum Btu hr the space can support 60 000 Btu hr Actual amount of Btu hr used The space in the above example is a confined space because the actual Btu hr used is more than the maximum Btu hr the space can support You must provide additional fresh air Your options...

Страница 6: ...ces from the floor ceiling and joining walls WARNING Rework worksheet adding the space of the adjoining unconfined space The combined space must have enough fresh air to supply all ap pliance in both spaces Ventilation from Outdoors If necessary provide extra fresh air by using ventila tion grills or ducts Connect these items directly to the outdoors or spaces open to the outdoors These include at...

Страница 7: ...evel For wall stud mounting locate one end of the mounting bracket over a wall stud WARNING Maintain minimum clearances shown in figure 7 If you can provide greater clearances from the floor and joining wall 2 Mark screw locations on wall see figure 7 3 Remove tape and mount bracket from wall Figure 7 Attaching to Wall Stud For attaching mounting bracket to wall studs 1 Drill holes at marked locat...

Страница 8: ...bottom mounting holes and wall anchor or drilled hole 7 Hold spacer in place with one hand With the other hand insert mounting screw through bottom mounting hole and spacer Place tip of screw in opening of wall anchor or drilled hole 8 Tighten both screws until heater is firmly secured to wall Do not over tighten Note Do not re place front panel at this time Re place front panel after making gas c...

Страница 9: ...ure Regulator Heater Cabinet Ground Joint Union Equipment Shutoff Valve From Gas Meter 4 W C to 10 5 W C Pressure Tee Joint 1 8 NPT Plug Tap Cap Pipe Nipple Tee Joint 3 8 NPT Pipe Nipple Sediment Trap Test Gauge Connection Reducer Bushing to 1 8 NPT 3 Minimum CHECKING GAS CONNECTIONS WARNING Test all gas piping and connections for leaks after installing or servicing Correct all leaks at once WARNI...

Страница 10: ...ld be plugged into a properly grounded three prong receptacle OPERATING YOUR HEATER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by pushing the ignitor button When lighting the pilot follow these instructions exact...

Страница 11: ...er for repairs If control knob does not pop up when released contact a qualified service person or gas supplier for repairs 8 When the pilot is lit turn control knob counterclockwise to heating level The main burner should light 9 To select the desired heat level turn the temperature setting knob counterclockwise to between 1 5 THERMOSTAT CONTROL OPERATION FOR IR20NGT IR30NGT The thermostatic cont...

Страница 12: ...istled brush to clean CLEANING BURNER PILOT AIR HOLE INLET We recommend that you clean the unit ever 2 500 hours of operation or every three months We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt To clean these parts we recommend using compressed air no greater than 30 psig This can be done by using a vacuum cleaner in the blow position using comp...

Страница 13: ...gas regulator 6 Turn Control knob to pilot position When ignitor button is pressed in there is a spark at the ODS pilot but no ignition 1 Control knob not fully pressed in 2 Control knob not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple damaged 5 Control valve damaged 1 Press in control knob fully 2 After ODS pilot lights keep control knob pressed in for 30 seconds...

Страница 14: ... ances see Figure 4 page 7 4 Clean burner orifice see Cleaning and Maintenance on pages 11 and 12 or replace burner orifice White powder residue forming within burner box or on adjacent walls or furni ture 1 When heated vapors from furniture polish wax carpet cleaners etc turn into white powder residue 1 Turn heater off when using furniture polish wax carpet cleaner or similar products Heater prod...

Страница 15: ...15 Installation Instructions and Owner s Manual Unvented Natural Gas Vent Free Room Heaters This page intentionally left blank ...

Страница 16: ...ssembly w Thermocouple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80074 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80056 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80107 Regulator 1 28 80069 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 800...

Страница 17: ...couple 1 23 801 10 Fan Assembly 1 9 80009 Orifice 1 24 80049 Fan Switch 1 10 80073 Orifice Adapter 1 25 8001 1 Ignitor Module Mounting Bracket 1 11 80055 Regulator Mounting Bracket 1 26 80019 Ignitor Pulse 1 12 80021 Regulator Connection 1 27 80014 Ignitor Wire 1 13 80083 Regulator 1 28 80068 Burner Left Bracket 1 14 80079 Gas Input Adapter 1 29 80013 High Limit Switch FAN 1 15 80069 Burner Right ...

Страница 18: ...or 1 7 80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80107 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 23 80014 Ignitor Wire 1 11 80009 Orifice 1 24 80013 High Limit Switch Fan 1 12 80021 Bracket Plenum Assembly 1 25 80049 Fan Switch 1 13 80081 Thermostat Valve 1 70342 Hardware Ki...

Страница 19: ...or 1 7 80079 Gas Input Elbow Adapter 1 20 801 10 Fan Assembly 1 8 80083 Regulator 1 21 8001 1 Ignitor Module Mounting Bracket 1 9 80021 Regulator Connection 1 22 80019 Ignitor Pulse 1 10 80055 Regulator Mounting Bracket 1 23 80014 Ignitor Wire 1 11 80009 Orifice 1 24 80013 High Limit Switch Fan 1 12 80033 Bracket Plenum Assembly 1 25 80049 Fan Switch 1 13 80081 Thermostat Valve 1 70342 Hardware Ki...

Страница 20: ...description of problem in all communication LIMITED WARRANTY Mr Heater Inc warrants its heaters and accessories to be free from defects in material and workmanship for a period of 1 year from date of purchase Mr Heater Inc will repair or replace this product free of charge if it has been proven to be defective within the 1 year period and is returned at customer expense with proof of purchase to M...

Отзывы: