Step 8:

 Place Cylinder Cap onto Post pull into place. 

 

  

   

 

 
 

Step 9: 

Assemble the Gas Line to the Burner Assembly 

and tighten.

 

 

  

   

 

 
 
 

Step 10:

 Leak Test #1:  

*Mix a leak check solution (1-part liquid dishwashing 

detergent to 3-parts water).  

*Connect the Hose and Regulator Assembly to the Gas 

Line and tighten. Then connect the Regulator to the 

propane cylinder.  

*Apply several drops of the leak check solution to the 

gas connection at the burner assembly.   

*Make sure that the heater control knob is turned “OFF”.   

*”Open” the Propane Cylinder Valve.   

*If bubbles appear at the connection, there is a leak and 

it must be tightened until no bubbles appear. MAKE 

SURE THERE IS NO LEAKS.   

*”Close” the Propane Cylinder Valve, then disconnect 

the Hose and regulator Assembly from the Propane 

Cylinder and the Gas Line 

 

Step 11:

 

(please read the NOTE)

 

Carefully insert the Gas Line into the Post.  

 Take great care not damage the flare fitting on the Gas 

Line that will connect to the Hose and Regulator. 

 

 

**NOTE: 

If your patio heater has a Bar Table, please assemble 

the table as Attachment 1, before Step 11.

 

 

\\Commserv\Users\EGI_Shared\Engineering\Labels & Manuals WIP\MH40PH\MH40PH Manual.doc 

Page 6 of 11 

06/08 Rev A

Содержание MH40PH

Страница 1: ...S HEATER GENERAL HAZARD WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOR...

Страница 2: ...at there is ample fresh air ventilation DO NOT use in buildings garages or other enclosed spaces If at any time gas odor is detected IMMEDIATELY DISCONTINUE operation until the source of gas has been...

Страница 3: ...efore you return Properly trained service people must repair the leak check for further leakages and them relight the appliance for you ODOR FADING NO ODOR DETECTED Some people cannot smell well Some...

Страница 4: ...e all components from package and inspect parts Packaging includes Nut Bolt Pack Containing 4pcs 3 16 24x3 8 screws 12pcs 1 4 20x3 4 bolts 12pcs 1 4 20 nuts 24pcs 1 4 flat washers 12pcs 1 4 lock washe...

Страница 5: ...has Wheels please assemble the wheels as Attachment 2 before Step 5 Attach 3 Legs Post Support Assembly to Base 6 bolts 1 4 20 3 4 12 flat washers 6 lock washers 6 nuts Step 6 Install Post onto Post...

Страница 6: ...OFF Open the Propane Cylinder Valve If bubbles appear at the connection there is a leak and it must be tightened until no bubbles appear MAKE SURE THERE IS NO LEAKS Close the Propane Cylinder Valve t...

Страница 7: ...several drops of the Leak Check Solution Step 10 to the hose gas line connection Make sure the Heater Control Knob is OFF Open the Propane Cylinder Valve If bubbles appear at the connection there is...

Страница 8: ...en the cylinder s valve and check all gas connection with a soap and water solution DO NOT USE A FLAME The gas connections to check include those in the heater base and the connections in the burner a...

Страница 9: ...ed in accordance with chapter 5 of the standard for Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 Only recoat those portions of the heater post base assembly with high temperature 120...

Страница 10: ...must show heater model number item number part number and description We recommend that only parts supplied by the manufacture be used on this unit A locally purchased part may appear to be identical...

Страница 11: ...Commserv Users EGI_Shared Engineering Labels Manuals WIP MH40PH MH40PH Manual doc Page 11 of 11 06 08 Rev A...

Страница 12: ...06 08 Rev A...

Отзывы: